Wu Zhengqiang,Wang Jiale,Yang Zhong,et al.Investigation on radioactivity levels in Dendrobium nobile Lindl. and its cultivation matrices in Chishui, Guizhou province[J].Chinese Journal of Radiological Medicine and Protection,2026,46(7):688-692
Investigation on radioactivity levels in Dendrobium nobile Lindl. and its cultivation matrices in Chishui, Guizhou province
Received:August 06, 2025  
DOI:10.3760/cma.j.cn112271-20250806-00282
KeyWords:Dendrobium nobile Lindl.  Radioactivity  Radionuclides  210Pb  Cultivation matrices
FundProject:贵州省卫生健康委科学技术基金项目(gzwkj2025-499);贵州省疾控中心青年科学基金项目(2023-E-3);李世军博士工作室项目(bsgzs2025-01)
Author NameAffiliationE-mail
Wu Zhengqiang Guizhou Center for Disease Control and Prevention, Guiyang 550003, China  
Wang Jiale Guizhou Center for Disease Control and Prevention, Guiyang 550003, China  
Yang Zhong Guizhou Center for Disease Control and Prevention, Guiyang 550003, China  
Meng Xiurou Guizhou Center for Disease Control and Prevention, Guiyang 550003, China  
Tian Zhujuan Guizhou Center for Disease Control and Prevention, Guiyang 550003, China 382610052@qq.com 
Wu Yutian Guizhou Center for Disease Control and Prevention, Guiyang 550003, China  
Liu Liya Guizhou Center for Disease Control and Prevention, Guiyang 550003, China  
Hits: 958
Download times: 4
Abstract::
      Objective To investigate the radioactivity level both in Dendrobium nobile Lindl (D. nobile) and its cultivation matrices in Chishui, Guizhou province, and analyze the correlation between them.Methods A total of 32 samples, including stems of D. nobile, Danxia stones, mosses, and source water, were collected from 8 major wild-simulated cultivation bases in Chishui where D. nobile is planted. The activity concentrations of 238U, 232Th, 226Ra, 40K, 210Pb and 137Cs in D. nobile, Danxia stones and mosses were determined by using high-purity germanium (HPGe) gamma spectrometer, and the gross α and gross β radioactivity in source water were determined by using low background α/β counter. Pearson correlation analysis was performed respectively for their activity concentrations. Results The mean activity concentrations in D. nobile were found to be 232Th (1.07 ± 0.30), 226Ra (1.04 ± 0.44), 40K (297.1 ± 62.1), 210Pb (157.1 ± 57.2), and 137Cs (0.093 ± 0.087) Bq/kg (dry weight), respectively, and 238U concentrations was below the detection limit. No statistically significant correlation (P > 0.05) was found of the activity concentrations of 232Th, 226Ra, 40K, 210Pb, and 137Cs in Danxia stones and of 232Th, 226Ra, 40K, and 137Cs in mosses with in D. nobile. However, a statistically significant correlation was observed of the activity concentrations of 210Pb in mosses and with in D. nobile (r= 0.90, P < 0.05). Conclusions The activity concentrations of 238U, 232Th, 226Ra, and 137Cs were all far below the limits specified in the national standard Limited Concentrations of Radioactive Materials in Foods (GB 14882-1994). Positive correlation was shown of the activity concentration of 210Pb between in D. nobile and in mosses.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:17875076  On-line:0

v
Scan QR Code
&et=9A2B3ECE8B55D590F309F17E6178CC7F0BDD8633AE155C57E932DAF702A4BF3D3D4677A28BEB0B61A6BC6AFD8515E668534595DBA902E73A428CC6C688B6B482C9070CFF1B237D5C9B4E8EB1B849FA3DA6555AAC261FA07DD81D9CAF9F10F0F571B9E4EFA2E8294305D9181CF410849CC9EC5A7CC0D75840A66BFEFCEB056F4F053AA5F816B3E87E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=AFBE687937F40C02&aid=&vid=&iid=DF92D298D3FF1E6E&sid=2A22E972FD97071B&eid=15F713CDE16A589C&fileno=20260708&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="AFBE687937F40C02"; var my_aid="";