Zhu Zhipeng,Lan Maoying,Ou Xue,et al.Selection of radiotherapy plans with different arc angles for left-sided breast cancer based on anatomical structures[J].Chinese Journal of Radiological Medicine and Protection,2025,45(9):884-891
Selection of radiotherapy plans with different arc angles for left-sided breast cancer based on anatomical structures
Received:June 25, 2025  
DOI:10.3760/cma.j.cn112271-20250625-00214
KeyWords:Deep inspiration breast hold (DIBH)  Anatomical structure  Left-sided breast cancer  Arc
FundProject:广西壮族自治区卫健委自筹课题(Z-A20230603,Z-A20230606);广东省医学科学技术研究基金(A2023250)
Author NameAffiliationE-mail
Zhu Zhipeng Department of Radiation Oncology, Second Affiliated Hospital of Guangxi Medical University, Nanning 530000, China  
Lan Maoying Department of Radiotherapy, First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510163, China  
Ou Xue Department of Radiation Oncology, Second Affiliated Hospital of Guangxi Medical University, Nanning 530000, China  
Li Guihua Department of Radiation Oncology, Second Affiliated Hospital of Guangxi Medical University, Nanning 530000, China  
Zheng Lianrong Department of Radiation Oncology, Second Affiliated Hospital of Guangxi Medical University, Nanning 530000, China 845150703@qq.com 
Hits: 7341
Download times: 883
Abstract::
      Objective To compare four postmastectomy radiotherapy plans with different arc angles for left-sided breast cancer prepared using deep inspiration breath hold (DIBH) technique, in order to explore the feasibility of selecting optimal arc angles based on the parameters of patients' anatomical structures. Methods A total of 51 patients who underwent postmastectomy radiotherapy for left-sided breast cancer using DIBH at the Second Affiliated Hospital of Guangxi Medical University and the First Affiliated Hospital of Guangzhou Medical University were selected. Among these, 40 patients selected using simple random sampling were treated with four radiotherapy plans with different arc angles, labeled as SV120, SV100, SV80, and SV60, while the remaining 11 patients were treated with only the SV60 plans. The dose parameters of the target volumes (TVs) and organs at risk (the heart, lungs, and contralateral breast), as well as the beam-on times of individual arcs, in these plans were compared. The parameters of the anatomical structures (i.e., the heart, lung, and breast) of the 51 patients, including PHeart, PLungl, and PBreast, were extracted. Taking these parameters as independent variables and the quality of the SV60 plans as the dependent variable, fitting was conducted using P(SV60)—a multivariate logistic regression model—based on a training set (45 patients) and a testing set (six patients). The classification threshold of the plans was set at 0.5. Results As the arc angle increased, the plans exhibited improved modulation capabilities for TVs and the left lung. However, the V5 of the right lung and the average beam-on time of a single arc also increased. The SV120 plans demonstrated significantly better V107% of planning target volume (PTV; 6.84%), homogeneity index (HI; 0.13), conformity index (CI; 0.81), and mean dose to the left lung (1330.97 cGy) compared to the other three types of plans, with statistically significant differences (W = 0-99,P < 0.001). The SV60 plans displayed lower mean doses to the contralateral breast (198.97 cGy) and the heart (440.35 cGy) and lower V5 of the right lung (0.27%) than the other three types of plans, with significant differences in V5 of the right lung and the mean dose to the contralateral breast (W = 0-157,P < 0.001). In contrast, no significant difference was observed in these parameters (except for V5 of the right lung) among the other three types of plans. The four types of plans exhibited average beam-on times of individual arcs of 22.0, 19.1, 16.1, and 14.4 s, respectively, with statistically significant differences (χ2 = 93.0,P < 0.001). A multivariate logistic regression model revealed that PLungl, PHeart, and PBreast were negatively correlated with the quality of the SV60 plans (t = -64.84, -28.20, -24.45, P < 0.001). This model yielded an accuracy of 93.33% and a precision of 92.86% in the training set, while its accuracy and precision reached 100% in the testing set. Conclusions For patients treated with postmastectomy radiotherapy for left-sided breast cancer using DIBH, it is feasible to select appropriate arc angles based on patients’ anatomical structures.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:17879471  On-line:0

v
Scan QR Code
&et=B4D843D3B1ADDD8B8FDFA7F2500B6C8155167B9053BD19EF5E893395E32CE7401C088ECFAB3959446A96AFF8863BB6333E6389C3A7CFEA9878522E1B66A1FC2FAD5D16051634F5DEFB314058B033D9321807A575F3142BF0ACC55FBEDB7CF0F69ED7CF73A4FBBF2F73AE8A98CAE8B3058B0B78D1E53E2584&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=E6A891D2134F30C0&aid=F52587CD9A012AC5AF25680E34A43807&vid=&iid=9CF7A0430CBB2DFD&sid=BEBF2238C7F1C1F1&eid=412FA1328E0CB9E9&fileno=20250908&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="E6A891D2134F30C0"; var my_aid="F52587CD9A012AC5AF25680E34A43807";