| Kang Feng,Xiao Detao,Cheng Weiqing,et al.Evaluation model and validation of activated carbon adsorption-based radon reduction effect in localized underground spaces[J].Chinese Journal of Radiological Medicine and Protection,2025,45(8):782-789 |
| Evaluation model and validation of activated carbon adsorption-based radon reduction effect in localized underground spaces |
| Received:April 15, 2025 |
| DOI:10.3760/cma.j.cn112271-20250415-00138 |
| KeyWords:Localized underground space Activated carbon Radon reduction by adsorption Effectiveness evaluation model |
| FundProject:国家自然科学基金(11875165) |
| Author Name | Affiliation | E-mail | | Kang Feng | School of Nuclear Science and Technology, University of South China/Radon Key Laboratory of Hunan Province, Hengyang 421001, China | | | Xiao Detao | School of Nuclear Science and Technology, University of South China/Radon Key Laboratory of Hunan Province, Hengyang 421001, China | xiaodt@usc.edu.cn | | Cheng Weiqing | School of Nuclear Science and Technology, University of South China/Radon Key Laboratory of Hunan Province, Hengyang 421001, China | | | Yang Rui | School of Nuclear Science and Technology, University of South China/Radon Key Laboratory of Hunan Province, Hengyang 421001, China | |
|
| Hits: 6657 |
| Download times: 1230 |
| Abstract:: |
| Objective To establish an evaluation model for the radon reduction effect of activated carbon adsorption in localized underground spaces, to guide the rational application of the activated carbon adsorption method for radon reduction in localized underground spaces. Methods For both intermittent and continuous adsorption-based radon reduction method in localized underground spaces, a theoretical model was constructed for evaluating the of radon reduction effec. By means of this modle, the influence factors on the radon reduction effect were analyzed such as radon concentration, space volume, and air exchange rate with the external environment. Experimental validation of the theoretical model was conducted under typical conditions. Results The radon exhalation rate from concrete surface in localized underground spaces was inversely linear relationship with the indoor radon concentration. However, the slope of this relationship was very small: when the radon concentration decreased from 2 018 Bq/m3 to 0, the exhalation rate only increased slightly from 4.20 to 4.46 Bq·m-2·h-1, indicating a minimal change. At the same air exchange rate and in the same space volume, the initial radon concentration had little impact on the adsorption-based radon reduction effect, thus suggesting that the radon generation rate from the enclosure surface could be negligible in the evaluation. In contrast, the adsorption flow rate of a radon reduction device and the air exchange rate between the localized spaces and surrounding environment had significant fluence on radon reduction effect. In the same sealed space and at the same adsorption flow rate, the difference in effect between intermittent and continuous adsorption method was of insignificance. However, in localized spaces with connectivity to surrounding environment, the continuous adsorption significantly outperforms intermittent adsorption, achieving faster radon reduction and better suitability for larger spaces. Simulated experiments validated that the theoretical model for evaluating adsorption-based radon reduction effect was reliable. Conclusions The research findings provide theoretical guidance on selecting appropriate adsorption-based radon reduction devices for localized underground spaces of different volumes and varing connectivity conditions, in order to reduce the radon concentration within localized spaces to expected levels. |
| HTML View Full Text View/Add Comment Download reader |
| Close |
|
|
|