Li Zhentao,Niu Yantao,Zhang Zongrui,et al.Statistics and application changes of resources for radiodiagnosis in 38 medical institutions in Beijing, China[J].Chinese Journal of Radiological Medicine and Protection,2025,45(6):566-572
Statistics and application changes of resources for radiodiagnosis in 38 medical institutions in Beijing, China
Received:May 22, 2024  
DOI:10.3760/cma.j.cn112271-20240522-00195
KeyWords:Medical irradiation  Examination frequency  Device for radiodiagnosis  Radiation worker
FundProject:
Author NameAffiliationE-mail
Li Zhentao Department of Radiology, Peking University People's Hospital, Beijing 100044, China  
Niu Yantao Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China ytniu163@163.com 
Zhang Zongrui Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China  
Liu Tao Department of Radiology, Peking University People's Hospital, Beijing 100044, China  
Lyu Gaoquan Department of Radiology, Peking University People's Hospital, Beijing 100044, China  
Hits: 156
Download times: 48
Abstract::
      Objective To investigate devices for radiodiagnosis used in medical institutions in Beijing, China, as well as radiation workers and the devices' application frequencies, in order to provide data support for determining radiation protection measures and allocating resources for clinical radiodiagnosis. Methods In October 2023, questionnaires were distributed to the members of the Radiation Technology Branch of the Beijing Medical Association who work in medical institutions at different levels across varying districts of Beijing. The collected data included information about devices for radiodiagnosis and radiation workers, as well as the application frequencies of various medical X-ray imaging devices during 2018-2022, in 38 medical institutions of Level 3 Grade A, Level 3, and Level 2 in 14 municipal districts of Beijing. Then, the collected data were organized using the Microsoft Power BI software to form report models, followed by the statistical analysis of data on the devices, radiation workers, and application frequencies were using the RStudio software. Results The 38 medical institutions in Beijing possess 591 devices for radiodiagnosis and 2 018 staff in the departments of radiology, including 1 037 radiologic technologists and 738 physicians, with 1.77 technologists and 1.26 physicians arranged for a single device on average. From 2018 to 2022, among all examinations of radiodiagnosis, computed tomography (CT) scans showed the highest frequencies, with total and average annual growth rates of 138.06% and 108.40%, respectively. Specifically, chest CT scans exhibited total and average annual growth rates of 225.20% and 122.50%, respectively. X-ray imaging ranked second in application frequency, with total average annual growth rates of 70.20% and 91.53%, respectively. Notably, chest X-ray imaging showed total and average annual growth rates of 63.89% and 89.41%, respectively. Conclusions From 2018 to 2022, X-ray imaging examinations displayed significantly fluctuating frequencies with an overall decline trend in the 38 medical institutions. In contrast, the CT scans showed increased frequencies, with chest CT scans displaying an increased frequency and proportion. This necessitates ensuring the justification of CT scans.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12030413  On-line:0

v
Scan QR Code
&et=4298BEE13DD0DB3F6C58C05588BCB402686FDCCEDE0142200E40A247B91C45318D3A699FFFE600E8D8EB7BD819B2A1FC23C1C7942EDD3857990FB023DF655D54E45439607D84E14C1729FC5786CED597CDDD7C0925F156B0586CEDC0D565E97B84FF962455EF7DD5C383753F5AA80E95&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=E6A891D2134F30C0&aid=&vid=&iid=B31275AF3241DB2D&sid=CDC418F38C4BFD60&eid=6A9657F54F754BF6&fileno=20250611&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="E6A891D2134F30C0"; var my_aid="";