Lei Limin,Zhou Yuhan,Guo Xiaoxu,et al.Feasibility of low-dose CT brain perfusion scanning based on deep learning reconstruction algorithm:a preliminary study[J].Chinese Journal of Radiological Medicine and Protection,2024,44(7):613-621
Feasibility of low-dose CT brain perfusion scanning based on deep learning reconstruction algorithm:a preliminary study
Received:October 20, 2023  
DOI:10.3760/cma.j.cn112271-20231020-00128
KeyWords:Deep learning image reconstruction algorithm  Acute ischemic stroke  Brain perfusion imaging  Low dose  Image quality
FundProject:河南省卫生健康委员会科技攻关项目(232102310098)
Author NameAffiliationE-mail
Lei Limin Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Zhou Yuhan Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Guo Xiaoxu Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Wang Hui Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Ma Jinping Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Wang Zhihao Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Cao Weimeng Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Gao Yuan Internal Medicine-Neurology of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Xu Yuming Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China  
Yue Songwei Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhenzhou 450052, China ysw197281@sina.com 
Hits: 2125
Download times: 790
Abstract::
      Objective To compare image quality and diagnostic parameters of whole-brain CT perfusion scans under different scanning conditions and assess the utility of deep learning image reconstruction algorithm (DLIR) in reducing tube current during low-dose scans. Methods Method A total of 105 patients with suspected acute ischemic stroke (AIS) were prospectively enrolled in the First Affiliated Hospital of Zhengzhou University from March, 2022 to March,203 and their baseline information was recorded. All patients underwent head non-contrast CT and CT perfusion (CTP) examinations. CTP scanning was performed at 80 kV in two groups with the tube current of 150 mA (regular dose) and 100 mA (low dose), respectively. The CTP images of 150 mA group were reconstructed using filtered back-projection algorithm as well as adaptive statistical iterative reconstruction-V (ASIR-V) at 40% and 80% strength levels, which were denoted as groups A-C. The CTP images of 100 mA group were reconstructed using ASIR-V80%, DLIR-M, and DLIR-H, which were denoted as groups D-F. Clinical baseline characteristics and radiation doses were compared between the two groups under different scanning conditions. Furthermore, we assessed the subjective and objective image quality, conventional perfusion parameters, and abnormal perfusion parameters of AIS patients across the six groups of reconstructed CTP images. Results Under the scanning conditions of 150 mA and 100 mA, 47 and 48 patients were diagnosed with AIS, respectively. There were no significant differences in the baseline characteristics between the two groups. However, there was a significant difference in the mean effective radiation dose (5.71 mSv vs. 3.80 mSv, t = 2 768.30, P < 0.001). The standard deviation (SD) of noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of gray matter (GM) and white matter (WM) were significantly different among the six groups of reconstructed images (F = 40.58-212.13, P < 0.001). In GM, the SD values in groups C, D, and F were lower than those in other groups (P < 0.05), and the SNR values in groups C and F were higher than those in other groups (P < 0.05). In WM, the SD and SNR values in groups C and F were significantly different from those in other groups (P < 0.05). Additionally, CNR values in groups C and F were higher than those in other groups (P < 0.05). There was no significant difference in subjective scores among groups B, C, and F (P > 0.05). Regarding perfusion parameters in the brain GM, groups D and E had lower cerebral blood volume (CBV) values compared to groups A to C (P < 0.05), and group F had lower CBV values than group B (P < 0.05). In the brain WM, group D had consistently lower mean transit time (MTT) values compared to the other groups (P < 0.05). Notably, there were no significant differences in AIS lesion detection rates and relevant diagnostic parameters across the six image groups. Conclusions Low-tube current CTP scan combined with the DLIR-H algorithm can enhance image quality without affecting perfusion parameters such as CBV and MTT, while reducing radiation dose by 30%. This algorithm can be routinely applied in brain CTP examinations.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029596  On-line:0

v
Scan QR Code
&et=08BA79BB04C4219FC27B2E2E3B1745EEB1C69D6AC504097A2C9A99AAFBAD83256D0B4F29F45A3549F4A35FD799D9B131EE80184DE18635E3B823AA9E3014C8748E10FD1022B7319EFEB070834032F566B4FB30EDFB4FD8003E77F46FD0ED5102B24BB2B9C5E8A1E90421CA8DDA56218D233E5A1F87BB87C0&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B80136CCD8DCBAA1&aid=B41687807C54E60392273C3AF72C99B2&vid=&iid=DF92D298D3FF1E6E&sid=9E7C0CB25117E09B&eid=BA3451F2C9E4FB70&fileno=20240710&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B80136CCD8DCBAA1"; var my_aid="B41687807C54E60392273C3AF72C99B2";