Zhang Xuan,Huang Jianwei,Li Dehong,et al.A method for radiation dose assessment of β-rays and γ-rays in mixed β-γ fields[J].Chinese Journal of Radiological Medicine and Protection,2024,44(7):608-612
A method for radiation dose assessment of β-rays and γ-rays in mixed β-γ fields
Received:August 11, 2023  
DOI:10.3760/cma.j.cn112271-20230811-00040
KeyWords:β-γ mixed radiation field  Thermoluminescent dosimeter  Personal dose monitoring
FundProject:中国计量科学研究院基本科研业务费项目(AKYCX2315)
Author NameAffiliationE-mail
Zhang Xuan National Institute of Metrology, Beijing 100029, China  
Huang Jianwei National Institute of Metrology, Beijing 100029, China  
Li Dehong National Institute of Metrology, Beijing 100029, China lidh@nim.ac.cn 
Cheng Jianbo National Institute of Metrology, Beijing 100029, China  
Hits: 2115
Download times: 782
Abstract::
      Objective To test a new method with thermoluminescent dosimeters (TLDs) to determine the β-ray and γ-ray doses of β-γ mixed radiation fields. Methods TLDs for personal dose monitoring were irradiated in the reference radiation fields of β-rays (90Sr/90Y, 85Kr) and γ-rays (137Cs). Across the range of 2.0-15.0 mSv, the linearity of TLD response and normalized response with respect to 137Cs were determined at the depths of Hp(10) and Hp(0.07). Using TLD detector readings at the depths of Hp(10) and Hp(0.07), β- and γ-ray doses in the mixed radiation fields were determined, and the result were verified. Results For Hp(10) and Hp(0.07) under γ-ray exposure and Hp(0.07) under β-ray exposure, the coefficient of determination (R2) were all >0.998. For the 90Sr/90Y source and85Kr source, the average values of response values normalized with respect to 137Cs at different doses were 1.14 and 0.18, respectively; and the normalized response values derived from the slope values of the dose-response curves for the two sources were 1.17 and 0.18, respectively. The ratios of measurements of Hp(10) to Hp(0.07), kR, for the 85Kr source were close to 0, while the kR values for the 137Cs source were close to 1. Using the average value of kR and the slope value of kR for calculation, the maximum relative deviations between the calculated values and conventional values for Hp(10)γ, Hp(0.07)γ, and Hp(0.07)β were 6.1% and 6.0%, respectively. Conclusions This method can be applied for the assessment of β-ray and γ-ray doses in β-γ mixed radiation fields of a single β source and single γ source.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12030318  On-line:0

v
Scan QR Code
&et=2D8A5CE31A4A632B42E93DA0B63635E8355738C754A01E442A2B00FCCFB3EDA43CAC5A28D56A239815FC0F05B75461A29483B25CF29703487AADE10AF29141319EA6FD19C7BAAC97DA668CC576A6C8D17B7E5D8C6FFB4AD6&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B80136CCD8DCBAA1&aid=B41687807C54E60399935ED703CC1B29&vid=&iid=DF92D298D3FF1E6E&sid=C7B13290323C226E&eid=EF9E84B2DA79FF23&fileno=20240709&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B80136CCD8DCBAA1"; var my_aid="B41687807C54E60399935ED703CC1B29";