Mao Yuxuan,Zhang Bingjie,Liu Yulong,et al.Analysis of the eye lens dose and annual effective dose to some interventional radiation workers in Xinxiang city[J].Chinese Journal of Radiological Medicine and Protection,2024,44(3):216-222
Analysis of the eye lens dose and annual effective dose to some interventional radiation workers in Xinxiang city
Received:August 16, 2023  
DOI:10.3760/cma.j.cn112271-20230816-00049
KeyWords:Interventional radiation workers  Eye lens  Annual effective dose
FundProject:国家自然科学基金(U2267220)
Author NameAffiliationE-mail
Mao Yuxuan Prevention and Treatment Center for Occupational Disease of Xinxiang City, Xinxiang 453000, China  
Zhang Bingjie Prevention and Treatment Center for Occupational Disease of Xinxiang City, Xinxiang 453000, China 15690789220@126.com 
Liu Yulong Second Affiliated Hospital of Soochou University, Suzhou 215004, China  
Wang Xuan Prevention and Treatment Center for Occupational Disease of Xinxiang City, Xinxiang 453000, China  
Liu Tongzhen Prevention and Treatment Center for Occupational Disease of Xinxiang City, Xinxiang 453000, China  
Jia Tianhe Prevention and Treatment Center for Occupational Disease of Xinxiang City, Xinxiang 453000, China  
Zhao Fengling Henan Institute for Occupational Medicine, Zhengzhou 450052, China  
Sun Quanfu 
1 Prevention and Treatment Center for Occupational Disease of Xinxiang City
, Xinxiang 453000, China

2 Second Affiliated Hospital of Soochou University
, Suzhou 215004, China

3 Henan Institute for Occupational Medicine
, Zhengzhou 450052, China

4 Key Laboratory of Radiological Protection and Nuclear Emergency
, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China

5 Xinxiang Municipal Health Commission
, Xinxiang 453000, China
 
 
Wang Dianhui 
1 Prevention and Treatment Center for Occupational Disease of Xinxiang City
, Xinxiang 453000, China

2 Second Affiliated Hospital of Soochou University
, Suzhou 215004, China

3 Henan Institute for Occupational Medicine
, Zhengzhou 450052, China

4 Key Laboratory of Radiological Protection and Nuclear Emergency
, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China

5 Xinxiang Municipal Health Commission
, Xinxiang 453000, China
 
 
Hits: 630
Download times: 281
Abstract::
      Objective To analyze the eye lens dose and annual effective dose to interventional radiation workers in some hospitals of Xinxiang city from 2020 to 2022, and to ascertain the dose to interventional radiation workers. Methods By using TLDs, the eye lens dose Hp(3) and annual effective dose Hp(10) were monitored for three consecutive years in six hospitals in Xinxiang city. The lens doses and annual effective doses to intervention radiation workers in different years in different-level hospitals and departments were analyzed. Results From 2020 to 2022, a total of 117 people were monitored. The left eye lens dose range was 0.12-164.24 mSv, and the right eye lens dose range was 0.07-51.64 mSv. The average annual dose was 8.56 mSv for left eye lens and 4.49 mSv for right eye lens The average annual dose distribution in the MDL-5 mSv range for the left and right eye lens was 60.68% and 73.50%, respectively. 9.41% (11 people) of the left eye lens doses exceeded 20 mSv. The annual effective doses range was 0.11-31.27 mSv, with average annual dose of 2.56 mSv. The proportion of average annual effective doses mainly distributed in the range of MDL to 1.25 mSv was 52.14%, with 2.56% annual effective dose exceeding 20 mSv. There was no significant difference in left and right eye lens dose and annual effective dose between the tertiary hospitals and the secondary hospitals in three years (P>0.05). Compared with different departments, the cumulative per capita dose in three years was statistically significant (left eye H=11.42, right eye H=13.72, annual effective dose H=25.94, P<0.05). The lens dose and annual effective dose in neurology department were lower than those in cardiology department and comprehensive intervention department (Zcardiology department=-3.33, -3.78, -4.83, P<0.05; Zcomprehensive intervention department=-2.71, -2.63, -4.39, P<0.05). Conclusions Most of the annual equivalent dose and annual effective dose to eye lens of the interventional radiation workers in Xinxiang city meet the national limits, but some of them have higher doses and exceed the national limits. It is suggested that the routine and continuous monitoring of eye lens doses to interventional radiologists should be strengthened while routine monitoring of annual effective dose, and attention should be paid to the eye lens and annual effective dose to interventional radiologists in secondary hospitals to improve the awareness of protection.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9568731  On-line:0

v
Scan QR Code
&et=6FD48CA0A0DD47593B531C92A19AC7AF21992563EA2185D2196B1FCAC274CF8042B6B41DABA7024B775686CE53CF64655310BE76D81A2D99D71A9AFD75EC533F1CAF899BF1BB006560D57C0C32836038A3C2DB57E6C8BF8919FDCABF1FEC072BF9EFE474A7878D4DE64017FF07AE6ADF38C718F5C1BBB251&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B80136CCD8DCBAA1&aid=&vid=&iid=38B194292C032A66&sid=CEC789B3C68C3BB3&eid=8B59EA573021D671&fileno=20240308&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B80136CCD8DCBAA1"; var my_aid="";