Zhou Lei,Cao Yiyao,Ren Hong,Wang Peng,Zou Hua,Yu Shunfei,Zhao Yaoxian,Xuan Zhiqiang,Lai Zhongjun,Zhang Dongxia.Investigation on total radioactivity in drinking water following operation of the second phase expansion project at Qinshan Nuclear Power Plant[J].Chinese Journal of Radiological Medicine and Protection,2023,43(12):1003-1009 |
Investigation on total radioactivity in drinking water following operation of the second phase expansion project at Qinshan Nuclear Power Plant |
Received:February 16, 2023 |
DOI:10.3760/cma.j.cn112271-20230216-00038 |
KeyWords:Qinshan Nuclear Power Plant Drinking water Gross α Gross β Radioactivity levels |
FundProject:浙江省卫生健康科技计划(2021KY613、2022RC120、2022KY130、2022KY132、2023KY643);浙南放射医学与核技术应用研究院开放课题(ZFY-2021-K-003、ZFY-2022-K-001, ZFY-2022-K-006) |
Author Name | Affiliation | E-mail | Zhou Lei | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Cao Yiyao | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | yycao@cdc.zj.cn | Ren Hong | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Wang Peng | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Zou Hua | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Yu Shunfei | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Zhao Yaoxian | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Xuan Zhiqiang | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Lai Zhongjun | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | | Zhang Dongxia | Zhejiang Province Center for Disease Control and Prevention, Hangzhou 310051, China | |
|
Hits: 818 |
Download times: 234 |
Abstract:: |
Objective To investigate and analyze the level of the gross radioactivity, and its variation trend, in surrounding drinking water since the second phase expansion project at Qinshan Nuclear Power Plant was officially put into operation.Methods From 2010 to 2022, the source water, factory water and tap water within 30 km of Qinshan Nuclear Power Plant were collected in the flood season (May) and dry period (October) every year. The total α and total β radioactivity concentrations in drinking water was measured and analyzed. The levels of total radioactivity in drinking water around different nuclear power plants in China and around non-nuclear power plant areas was compared.Results The mean radioactivity concentrations of total α and total β were (0.021±0.019) and (0.204±0.058) Bq/L in source water, (0.010±0.005) and (0.185±0.056) Bq/L in factory water, and (0.012±0.007) and (0.170±0.058) Bq/L in tap water, respectively, all lower than the limits stipulated in the Sanitary Standards for Drinking Water. There were no significant differences in the monitoring result of betweem the three types of water samples both in the flood and dry periods (P> 0.05). The total radioactivity level in drinking water around Qinshan Nuclear Power Plant site was close to that in drinking water around different nuclear power plants in China and around areas without nuclear power plants.Conclusions Following the second phase of the expansion project officially being put into operation, the total α and β radioactivity level in drinking water around the Qinshan Nuclear Power Plant has been in a stable trend and lower than the guidance level given in national standard. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|