Zhang Jie,Luo Chunli,Liu Nan,Zhang Wenjun,Yu Lang,Qiu Jie.Clinical commissioning of the Flexitron afterloader[J].Chinese Journal of Radiological Medicine and Protection,2023,43(11):893-899
Clinical commissioning of the Flexitron afterloader
Received:April 28, 2023  
DOI:10.3760/cma.j.cn112271-20230428-00133
KeyWords:Flexitron afterloader  Clinical commissioning  Brachytherapy
FundProject:中央高水平医院临床科研项目(2022-PUMCH-B-052);中央高水平医院临床科研青年培优计划项目(2022-PUMCH-A-101)
Author NameAffiliationE-mail
Zhang Jie Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China  
Luo Chunli Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China  
Liu Nan Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China  
Zhang Wenjun Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China  
Yu Lang Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China yulang@pumch.cn 
Qiu Jie Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China  
Hits: 718
Download times: 247
Abstract::
      Objective To formulate clinical commissioning procedures, items, and testing method for Flexitron afterloader hardware and software and establish relevant quality control procedures in order to meet national standards and clinical requirements.Methods Clinical commissioning included hardware, treatment planning system (TPS), and end-to-end (ETE) full-process testing. The radioactive source positioning accuracy was measured using a source position check ruler. The accuracy and linearity of dwell time were evaluated using three method: stopwatch timing, ion chamber measurement, and video analysis. The accuracy of source position simulator, connecting tubes, source position check ruler, and other measuring tools was tested using a high-precision ruler. Films were used for calibration of marker lines and applicators. The electrometer and well chamber were used to calibrate the radioactive source activity. The display and reconstruction accuracies of the TPS were evaluated using physical image data. ETE testing was conducted using a custom-made phantom for scanning, planning, and dose measurement.Results The accuracy testing result of the commissioning items were within acceptable limits. The deviation in source activity measurements was 0.21%, and the ETE point dose measurement deviation was 2.32%, both of which met the clinical requirements. However, there was a 2 mm difference between the nominal and measured values of the magnetic resonance marker line in the accuracy testing items. Therefore, adjustments were required when using marker line for catheter reconstruction based on magnetic resonance images.Conclusions By summarizing the clinical commissioning experience of the Flexitron afterloader, this study has developed quality control method and baseline levels of result of afterloader and TPS items, which provides a reference for the commissioning before clinical use.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9075053  On-line:0

v
Scan QR Code
&et=3C06DB566315F8DCAF6E1B8E6CD7809E1F0CF3CE78FE71D93B45D52C0684FA637E071EF683107139FEA09FA3E2FED0C845A82324F1FE54C0&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BA1E75DF0B7E0EB2&aid=6680D355800CC8EE7858BA0EBD715FB9&vid=&iid=708DD6B15D2464E8&sid=3DC9CEF02B8360EE&eid=7E7F5B01D43BD73F&fileno=20231107&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BA1E75DF0B7E0EB2"; var my_aid="6680D355800CC8EE7858BA0EBD715FB9";