Su Yinping,Zhang Pinhua,Cui Shiyue,Li Xiaoliang,Liu Jianxiang,Sun Quanfu,Deng Jun.The investigation and analysis of eye lens dose to interventional radiology workers in China from 2019 to 2021[J].Chinese Journal of Radiological Medicine and Protection,2023,43(6):457-461
The investigation and analysis of eye lens dose to interventional radiology workers in China from 2019 to 2021
Received:February 10, 2023  
DOI:10.3760/cma.j.cn112271-20230210-00033
KeyWords:Occupational exposure  Interventional radiology  Eye lens  Dose monitoring
FundProject:
Author NameAffiliationE-mail
Su Yinping Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Zhang Pinhua Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Cui Shiyue Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Li Xiaoliang Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Liu Jianxiang Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China liujianxiang@nirp.chinacdc.cn 
Sun Quanfu Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Deng Jun Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Hits: 1183
Download times: 431
Abstract::
      Objective To investigate and analyze the eye lens dose to interventional radiology workers in China from 2019 to 2021.Methods The monitoring data on eye lens dose to interventional radiology workers from 31 province-level units during 2019-2021 were collected through the National Radiological Health Information Platform. The eye lens dose evaluation indicator was Hp(3), with each monitoring period of no more than 3 months. Kusall-Wallis H test was used for the comparison of multiple groups and pairwise.Results A total of 6 643 interventional radiology workers were investigated from 2019 to 2021. The average annual eye lens dose was 1.03 mSv, with the median of 0.17 mSv and the maximum of 94.88 mSv. The annual eye lens dose to 59 workers exceeded 20 mSv. It was also found that the annual eye lens dose to the doctors in 2019 and 2020 was slightly higher than that to nurses (rank mean difference=118.29, 129.71, P<0.01), and the lens dose to interventional radiology workers who performed cardiac interventions in 2019 was higher than that to workers who performed peripheral vascular interventions (rank mean difference=46.52, P<0.05).Conclusions The lens dose to interventional radiology workers is lower than the limits given in Chinese national standard currently in effect, but exceed the latest internationally recommended limit for a few ones. In order to protect the occupational health of interventional radiology workers, the monitoring of lens dose should be strengthened.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9067426  On-line:0

v
Scan QR Code
&et=640A177CCC182B56AF4FC73398B91DF1DA55F0FC96651E5C393EFA04D6B8B0EF1F94AC6B63AF28890FB527367898523758C54DD2711109B591149478D3C9935065386081D5ABB5AFBC4DC0C28933330AA0126992FA22A9E13B3F9A7F29317056E6A341330B2855BBDCF01648DB995DF0&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BA1E75DF0B7E0EB2&aid=7F24A11D2A9724EB3E40A50C3908FEFC&vid=&iid=B31275AF3241DB2D&sid=D0E8F9CBDBE0070C&eid=FCACFF68346F8D4F&fileno=20230609&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BA1E75DF0B7E0EB2"; var my_aid="7F24A11D2A9724EB3E40A50C3908FEFC";