Gao Jun,Zhu Yadi,Wang Yongfeng,et al.Development of dose verification methods for boron neutron capture therapy[J].Chinese Journal of Radiological Medicine and Protection,2023,43(3):228-233
Development of dose verification methods for boron neutron capture therapy
Received:November 15, 2022  
DOI:10.3760/cma.j.cn112271-20221115-00448
KeyWords:Boron neutron capture therapy  Neutron dose measurement  Dose verification
FundProject:
Author NameAffiliationE-mail
Gao Jun International Academy of Neutron Science, Qingdao 266199, China
Institute of Neutron Science(Chongqing) Co., Ltd., Chongqing 401331, China 
 
Zhu Yadi Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
University of Science and Technology of China, Hefei 230026, China 
 
Wang Yongfeng International Academy of Neutron Science, Qingdao 266199, China
Institute of Neutron Science(Chongqing) Co., Ltd., Chongqing 401331, China 
 
Jin Chufeng International Academy of Neutron Science, Qingdao 266199, China  
Ji Xiang International Academy of Neutron Science, Qingdao 266199, China xiang.ji@fds.org.cn 
Hits: 3611
Download times: 2170
Abstract::
      To summarize the progress in BNCT dose verification method in the world and discusses their development prospects. Boron neutron capture therapy (BNCT) utilizes the specific capture reaction between the neutrons and boron drugs enriched in tumor cells to selectively kill tumor cells. In order to verify the accuracy of the radiotherapy plan and ensure the therapeutic effect on patients, it is necessary to measure the dose before treatment and compare the experimental radiation dose with the planned dose. The current BNCT dose measurement method mainly include point dose measurement method based on ionization chambers, thermoluminescence dosimeters and activation foils, two-dimensional dose measurement method based on films, and three-dimensional dose measurement method based on gel dosimeters.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029988  On-line:0

v
Scan QR Code
&et=A90EAC7419FB9B2298E2BD8726CB79814066AF60D2CDA273C1580CDD00767EC37FBB8339A549CCE1E187749769BFBC2976308D89738538F70D4C9511E81D02A138B275D103C04384FBEE83D0EB2E3B66&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BA1E75DF0B7E0EB2&aid=443087E59E7597C05F3FBC8044C68528&vid=&iid=38B194292C032A66&sid=CA5852BD1A173B3A&eid=FD7C952458BFB5D8&fileno=20230311&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BA1E75DF0B7E0EB2"; var my_aid="443087E59E7597C05F3FBC8044C68528";