Wang Yunhan,Sun Yanan,Li Peng,Yang Jianwei,Wang Xiaohui,Zhang Zhenqin,Zheng Xiaoli,Luo Hui,Ye Ke,Ge Hong.Prognostic value of metabolic parameters of 18F-FDG PET/CT in advanced non-small cell lung cancer treated with first-line immunotherapy combined with chemotherapy[J].Chinese Journal of Radiological Medicine and Protection,2023,43(2):87-93
Prognostic value of metabolic parameters of 18F-FDG PET/CT in advanced non-small cell lung cancer treated with first-line immunotherapy combined with chemotherapy
Received:August 10, 2022  
DOI:10.3760/cma.j.cn112271-20220810-00327
KeyWords:18F-FDG  Immunotherapy combined with chemotherapy  Total metabolic tumor volume
FundProject:河南省科技攻关项目(222102310015);河南省医学科技攻关项目(SBGJ202102056)
Author NameAffiliationE-mail
Wang Yunhan Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Sun Yanan Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Li Peng PET/CT Center of Henan Province, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Yang Jianwei PET/CT Center of Henan Province, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Wang Xiaohui Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Zhang Zhenqin Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Zheng Xiaoli Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Luo Hui Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Ye Ke Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China  
Ge Hong Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou 450008, China gehong666@126.com 
Hits: 1403
Download times: 384
Abstract::
      Objective To investigate the prognostic value of metabolic parameters of 18F-fluorodeoxyglucose (18F-FDG) positron emission computed tomography/computed tomography(PET/CT) in advanced non-small cell lung cancer(NSCLC) treated with first-line immune checkpoint inhibitor (ICI) combined with chemotherapy.Methods A retrospective study was conducted to evaluate patients with advanced NSCLC who underwent baseline PET/CT before treatment at the Affiliated Cancer Hospital of Zhengzhou University from 2019 to 2021. Receiver operating characteristic (ROC) curve analysis was used to determine the cut-offs for metabolic parameters of PET/CT, including total metabolic tumor volume (TMTV), total lesion glycolysis (TLG), and maximum standard uptake value (SUVmax). Kaplan-Meier method, Log-rank test, and Cox regression model were used to calculate the overall survival (OS) and the progression-free survival(PFS).Results A total of 44 patients were enrolled. Univariate analysis showed that the factors influencing PFS were TMTV and the number of metastatic sites (χ2=4.19, 11.28,P<0.05) and the factors influencing OS were TMTV and TLG (χ2=14.96, 6.05,P<0.05). Multivariate analysis suggested that number of metastatic sites was an independent prognostic marker for PFS (P=0.011) and TMTV was an independent prognostic marker for OS (P=0.038).Conclusions TMTV is a prognostic indicator of OS while the number of metastatic sites is a prognostic indicator of PFS in advanced NSCLC patients who received first-line ICI combined with chemotherapy, but further prospective studies are needed.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9080305  On-line:0

v
Scan QR Code
&et=B172190E08D194BB7A72C6B4CD06A48BAAEAEBA8F125B72DD5F6DEB97F2949EB94E7B553D65E3DB414D072361136B7B62291DB37F5FD8A13D80E3759A4F0D0222D025CDAF6A78F1BA546456DB421244BE1F12EA1B41588A8E0D473EAA5B3868A5D17F566E71B9FD37D922FED31A0BE1936D71DFF355D631FF4F05D314E2C6175345C633BB50A065C922205C6B6BC3A1DE07E6A4AF546AE98C8383E55C40DA1CD5B41F4EDE8D02D940A6AF0A0452D5A49&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BA1E75DF0B7E0EB2&aid=F7D0025B820CBB4B3521C2C7A6068697&vid=&iid=0B39A22176CE99FB&sid=117F81797AB182FC&eid=39EEF47180459690&fileno=20230202&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BA1E75DF0B7E0EB2"; var my_aid="F7D0025B820CBB4B3521C2C7A6068697";