Xu Mingfa,Lin Chen,Jia Libo,Chang Qing,Xiang Huiyun,Yu Huijun.Levels and variation of radon equilibrium factor in an office of Nanning city[J].Chinese Journal of Radiological Medicine and Protection,2022,42(8):636-640
Levels and variation of radon equilibrium factor in an office of Nanning city
Received:December 20, 2021  
DOI:10.3760/cma.j.cn112271-20211220-00487
KeyWords:Radon concentration  Equilibrium equivalent radon concentration  Equilibrium factor  Continuous measurement
FundProject:
Author NameAffiliationE-mail
Xu Mingfa Guangxi Zhuang Autonomous Region Radiation Environmental Supervision and Management Station, Nanning 530022, China  
Lin Chen Ionization Monitoring Department, Guangxi Zhuang Autonomous Region Radiation Environmental Supervision and Management Station, Nanning 530022, China  
Jia Libo Ionization Monitoring Department, Guangxi Zhuang Autonomous Region Radiation Environmental Supervision and Management Station, Nanning 530022, China  
Chang Qing Ionization Monitoring Department, Guangxi Zhuang Autonomous Region Radiation Environmental Supervision and Management Station, Nanning 530022, China  
Xiang Huiyun Radiation Environment Analysis and Test Center, Guangxi Zhuang Autonomous Region Radiation Environmental Supervision and Management Station, Nanning 530022, China 775217654@qq.com 
Yu Huijun Ionization Monitoring Department, Guangxi Zhuang Autonomous Region Radiation Environmental Supervision and Management Station, Nanning 530022, China  
Hits: 1461
Download times: 451
Abstract::
      Objective To study the levels and variation of equilibrium factor in indoor environment.Methods A one-year continuous measurement of radon concentration and equilibrium equivalent radon concentration was carried out in an indoor office building of Nanning city. The effective data acquisition rates of radon gas and radon progeny were 99.9% and 86.7%, respectively.Results The annual average activity concentration and equilibrium equivalent radon concentration in indoor environment were (50.9±20.7)and (15.5±10.1)Bq/m3, both of which had the same diurnal and seasonal variation. The average annual value of equilibrium factor was 0.30±0.12, showing no obvious diurnal variation. The distribution of monthly mean value of equilibrium factor showed a similar trend to that of radon and radon progeny. The highest and the lowest value appeared in November and June, respectively, with 0.47±0.24 and 0.19±0.06.Conclusions Due to the large variation range of monthly mean value of equilibrium factor in indoor environment, when annual effective dose of radon exposure was estimated based on radon gas concentration, attention should be paid to choose the quantity value of equilibrium factor and the uncertainty caused by the change of equilibrium factor should be considered.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9058259  On-line:0

v
Scan QR Code
&et=BC9ADA20E685FA30DFFEEE1E659BE911AE3E623A33F5CC3AD7A8ED0A9D1FC77832CDC125FD1F68CA7499890CEC472773588EF56E48AD322A790D01D3670DCC48E9C9FD05ACF39085A81204DD9D044FE1&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=68F7EBB7E610720FC2335B22C44CEACC&vid=&iid=5D311CA918CA9A03&sid=9BF3B0483F192149&eid=DB7B2C790D19BE6E&fileno=20220811&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="68F7EBB7E610720FC2335B22C44CEACC";