Liu Hongming,Chen Bo,Zhuo Weihai.Simulation of detection efficiency of a portable NaI(Tl) γ spectrometer for monitoring 131I in the thyroid[J].Chinese Journal of Radiological Medicine and Protection,2022,42(8):618-623
Simulation of detection efficiency of a portable NaI(Tl) γ spectrometer for monitoring 131I in the thyroid
Received:April 20, 2022  
DOI:10.3760/cma.j.cn112271-20220420-00168
KeyWords:131I  Thyroid-neck phantom  Portable gamma spectrometer  Detection efficiency  Monte Carlo simulation
FundProject:国家自然科学基金(11775053,12175043)
Author NameAffiliationE-mail
Liu Hongming Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Chen Bo Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Zhuo Weihai Institute of Radiation Medicine, Fudan University, Shanghai 200032, China whzhuo@fudan.edu.cn 
Hits: 1457
Download times: 453
Abstract::
      Objective To simulate the effects of different thyroid-neck phantoms and monitoring positions on the detection efficiency of portable γ spectrometer, and to provide guidance for more accurate on-site measurement of 131I activity in the human thyroid.Methods Based on the models of 4 typical thyroid-neck phantoms and a 3-inch NaI (TI) γ spectrometer used for the measurement of 131I in the thyroid and combined with the possible field monitoring scenarios, the Monte Carlo method was used to simulate and calculate the detection efficiency of the spectrometer under different conditions of monitoring distance, thyroid depth and thyroid volume.Results The detection efficiency decreased significantly with the increase in the distance between the detector and the neck surface. The efficiency close to the neck surface was about 15 times that at 15 cm away from the neck surface. The detection efficiency decreased significantly with the increase in thyroid depth. When it was measured at the surface of the neck, the detection efficiency of thyroid at depth of 2 mm was about 3.6 times that of 30 mm. The detection efficiency decreases with the increase in thyroid volume. When it was measured at the neck surface, the detection efficiency of thyroid with 1 ml volume was 1.71 times that with 30 ml. The detection efficiency decreased with the center-point offset of the detector, especially at the neck surface, an offset of 2 cm would reduce the detection efficiency by about 15%.Conclusions Not only the measurement distance used in calibration, but also the information of the depth and volume of thyroid in the neck-thyroid phantom, is important to know in advance for an accurate measurement of 131I activity in thyroid by using a portable gamma spectrometer.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9066011  On-line:0

v
Scan QR Code
&et=DCB591F1B485B602D903B99489861A38A5FF7C0FB2BAA5581643DF5A5B8B75D88AD74E3421976E926E0A8B6DE975034522645445778B5BC50D33E4E04E931B44ABF7AA8053E18E6654CE3E66654E41EBB42A58349CD69663455E30E86364AC169355B0C80B83EA792AB97BBBA082F9E787E8061B606D6357&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=68F7EBB7E610720FAED2083D27E2E531&vid=&iid=5D311CA918CA9A03&sid=54E527C5B72E59D8&eid=F8AEC975DBDD7F2F&fileno=20220808&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="68F7EBB7E610720FAED2083D27E2E531";