Sun Weihang,Zhang Lin,Niu Fei,Xu Jiaang,Min Nan,Yang Shuhui,Liu Fang,Li Tiantian,Zhu Jianguo.Monitoring results and analysis of 131I in the air of workplace treated with iodine[J].Chinese Journal of Radiological Medicine and Protection,2021,41(12):906-911
Monitoring results and analysis of 131I in the air of workplace treated with iodine
Received:August 17, 2021  
DOI:10.3760/cma.j.issn.0254-5098.2021.12.005
KeyWords:Thyroid cancer  131I treatment  Air sampling  Iodine box  Internal radiation
FundProject:
Author NameAffiliationE-mail
Sun Weihang Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250117, China  
Zhang Lin Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250117, China  
Niu Fei College of Preventive Medicine, Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250012, China  
Xu Jiaang College of Preventive Medicine, Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250012, China  
Min Nan College of Preventive Medicine, Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250012, China  
Yang Shuhui College of Preventive Medicine, Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250012, China  
Liu Fang College of Preventive Medicine, Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250012, China  
Li Tiantian Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250117, China  
Zhu Jianguo College of Preventive Medicine, Shandong First Medical University(Shandong Academy of Medical Sciences), Jinan 250012, China 13031737690@163.com 
Hits: 2469
Download times: 863
Abstract::
      Objective To understand the activity concentration of 131I aerosol in the air of the iodine treatment workplace and estimate the internal dose of 131I inhaled by medical staff in nuclear medicine. Methods Using CF-1001BRL portable large capacity air sampler, the 131I aerosol in the iodine treatment workplace of nuclear medicine department of 6 hospitals in Shandong province was collected by iodine box, and the HPGe-γ energy spectrometer was used to measure the samples. The 131I activity concentration in iodine treatment workplace at 6 hospitals was obtained, and the internal dose to medical staff was estimated. Results The 131I activity concentration in the air in iodine treatment workplaces at 6 hospitals ranged from 3.64 to 2.94×103 Bq/m3. The 131I activity concentration in the controlled area (ward, patient passageway, subpacking room, operation administration room) was significantly higher than that in the supervised area. The highest 131I activity concentration, 2.62×102 Bq/m3, in the supervised area was found in the medical care passageway. The estimated effective dose to nuclear medicine workers was 0.07-5.68 mSv, not exceeding the national limit. Conclusions The phenomenon of 131I aerosol contamination still exists in the iodine treatment workplaces of nuclear medicine departments in hospitals, so it is necessary to carry out internal radiation monitoring for nuclear medicine departments all around the country, and explore more reasonable protection standards and methods.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9071755  On-line:0

v
Scan QR Code
&et=3CBA26923B1509143A16FC896CF6957158E3A8D841253FE657A39D321E5D43D8FF37012D06F0B8A3474FA46883EB3A4BC3D754A0663FAC60C82D11A4EABB54C752C192AB81BB1FECEBC079D6D1F98D7A9D5F372B914A7C82B3675B1312562ECC&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=AA4FE43705B0D4A7D1AEFBDB30784609&vid=&iid=59906B3B2830C2C5&sid=0FCE62EC9DC00F5E&eid=58AAF01A97187A3A&fileno=20211205&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="AA4FE43705B0D4A7D1AEFBDB30784609";