Zhang Qilin,Wang Mingqing,Zhang Shuming,Zhuang Hongqing,Jiang Ping,Qu Ang,Jiang Weijuan,Wang Hao,Yang Ruijie.The feasibility study of generalization of knowledge-based planning for cervical cancer[J].Chinese Journal of Radiological Medicine and Protection,2021,41(5):327-333
The feasibility study of generalization of knowledge-based planning for cervical cancer
Received:December 04, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2021.05.002
KeyWords:Radiotherapy  Automatic planning  Cervical cancer
FundProject:国家自然科学基金(81071237,81372420);北京市自然科学基金(7202223);首都卫生发展科研专项(2020-2Z-40919);北京市科学技术委员会协同创新项目(Z201100005620012)
Author NameAffiliationE-mail
Zhang Qilin Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Wang Mingqing Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Zhang Shuming Department of Ultrasound, Beijing Hospital, Beijing 100730, China  
Zhuang Hongqing Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Jiang Ping Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Qu Ang Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Jiang Weijuan Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Wang Hao Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Yang Ruijie Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China ruijyang@yahoo.com 
Hits: 2348
Download times: 961
Abstract::
      Objective To design a knowledge-based cervical cancer planning model and apply it to cases of endometrial cancer and rectal cancer in order to explore the generalization of the model. Methods A total of 179 cases of pelvic regions with different prescribed doses of dual-arc volumetric modulated arc therapy clinical plans were collected, of which 99 cases of cervical cancer clinical plans with a prescribed dose of 50.4 Gy were used as the training set to establish the RapidPlan model, and the remaining clinical plans were divided into 4 validation groups with 20 cases in each group. The clinical plans for cervical cancer and endometrial cancer with a prescription dose of 50.4 Gy were named groups A and B, while the clinical plan for endometrial cancer and rectal cancer with a prescription dose of 45 Gy were named groups C and D. The model was used to redesign the clinical plans in the 4 groups and the automatic plans were obtained. The planning target volume (PTV) and organ at risk (OAR) dosimetry parameters were compared between automatic plans and clinical plans. Results The conformity index (CI) of the automatic plans in the A, B, C, and D groups were equivalent to that of the clinical plans (P>0.05). The homogeneity index (HI) and D2% of the automatic plans in groups A, B, and C were all lower than those in clinical plans(HI, Z=-3.248, -3.360, -2.329,P<0.05;D2%,Z=-2.987, -3.397, -2.442,P<0.05). The HI and D2% of the automatic plans in group D were similar those in the clinical plans (P>0.05). While ensuring the PTV coverage, the average value of OAR dosimetry parameters in all automatic plans groups were lower than that of the clinical plans. Conclusions The RapidPlan model established by the cervical cancer clinical plans can complete the automatic plan design for endometrial cancer and rectal cancer under different prescription doses, which preliminarily proves the possibility of the generalization of the RapidPlan model.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9059770  On-line:0

v
Scan QR Code
&et=876B4A42438D29B34F8569CFA947824DEC63262CF53FCA3763764E300FCEA295F76C335A71D4B6AF1273FE59C1F8D3E970E1D61323DCD032BC9F27CCCEC18597E0A0BF7912EE9D418F11ACD1E4FF7F0C13A5C5B6AB691D4F&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=512ADBF3DF5B950305D9A222BD4CC5DE&vid=&iid=94C357A881DFC066&sid=170CE8B011EA4FD9&eid=CF6CB42CFF3D4C4E&fileno=20210502&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="512ADBF3DF5B950305D9A222BD4CC5DE";