Zhang Zhen,Wang Xuetao,Hou Changsong,Lian Dexing,Zhu Weiguo,Chen Fei,Li Yuwen.Shielding calculation and discussion on high energy light source storage ring and synchrotron[J].Chinese Journal of Radiological Medicine and Protection,2021,41(2):146-150 |
Shielding calculation and discussion on high energy light source storage ring and synchrotron |
Received:January 16, 2020 |
DOI:10.3760/cma.j.issn.0254-5098.2021.02.012 |
KeyWords:Synchrotron radiation Monte Carlo simulation Ambient dose equivalent |
FundProject:四川省科技厅社会发展重点研发计划(2020YFS0437);四川省卫生健康委员会重点课题(18ZD049) |
Author Name | Affiliation | E-mail | Zhang Zhen | National Center for Occupational Safety and Health, BHC, Beijing 102308, China | | Wang Xuetao | National Center for Occupational Safety and Health, BHC, Beijing 102308, China | | Hou Changsong | Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Lian Dexing | Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Zhu Weiguo | Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Chen Fei | National Center for Occupational Safety and Health, BHC, Beijing 102308, China | | Li Yuwen | National Center for Occupational Safety and Health, BHC, Beijing 102308, China | lyw_2006_lyw@163.com |
|
Hits: 2439 |
Download times: 1228 |
Abstract:: |
Objective To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source. Methods The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding. Results The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%. Conclusions For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|