Zhang Zhen,Wang Xuetao,Hou Changsong,Lian Dexing,Zhu Weiguo,Chen Fei,Li Yuwen.Shielding calculation and discussion on high energy light source storage ring and synchrotron[J].Chinese Journal of Radiological Medicine and Protection,2021,41(2):146-150
Shielding calculation and discussion on high energy light source storage ring and synchrotron
Received:January 16, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2021.02.012
KeyWords:Synchrotron radiation  Monte Carlo simulation  Ambient dose equivalent
FundProject:四川省科技厅社会发展重点研发计划(2020YFS0437);四川省卫生健康委员会重点课题(18ZD049)
Author NameAffiliationE-mail
Zhang Zhen National Center for Occupational Safety and Health, BHC, Beijing 102308, China  
Wang Xuetao National Center for Occupational Safety and Health, BHC, Beijing 102308, China  
Hou Changsong Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Lian Dexing Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Zhu Weiguo Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Chen Fei National Center for Occupational Safety and Health, BHC, Beijing 102308, China  
Li Yuwen National Center for Occupational Safety and Health, BHC, Beijing 102308, China lyw_2006_lyw@163.com 
Hits: 2439
Download times: 1228
Abstract::
      Objective To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source. Methods The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding. Results The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%. Conclusions For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9068179  On-line:0

v
Scan QR Code
&et=79DC92D373DF3A733E7B0638A98B122EF7178BECA6D8A5B0FB8E8BB59A68EFC7326945EEB2D2D883AB2AECD5F312478199805A3553B34993375E8E5A7CE11E319F45B34B07440AD72DE5F891761FFA524561AFA5B029810F2D4AA5058BF08DB0&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=C76A7301F1A8EE48A176516E1A3D1345&vid=&iid=0B39A22176CE99FB&sid=A020552C37306588&eid=2DBBF45CC176713E&fileno=20210212&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="C76A7301F1A8EE48A176516E1A3D1345";