Guo Weizhen,Liu Xiaolian,Qiu Meijiao,Li Mingfang,Zhang Sufen,Mai Weiji,Jia Yuxin.Exploring the investigation level for individual monitoring for medical radiation workers in Guangdong province[J].Chinese Journal of Radiological Medicine and Protection,2021,41(2):128-133
Exploring the investigation level for individual monitoring for medical radiation workers in Guangdong province
Received:November 04, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2021.02.009
KeyWords:Guangdong province  Medical radiographer  Investigation level  Individual dose
FundProject:
Author NameAffiliationE-mail
Guo Weizhen Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China  
Liu Xiaolian Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China  
Qiu Meijiao Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China  
Li Mingfang Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China  
Zhang Sufen Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China  
Mai Weiji Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China  
Jia Yuxin Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou 510300, China jiayx333@163.com 
Hits: 2023
Download times: 1019
Abstract::
      Objective To explore the investigation level of individual monitoring for medical radiation workers. Methods Monitoring and analysis of individual doses to the medical radiation workers in Guangdong province were performed, from 2016 to 2019, by the Individual Dose Monitoring Department of Guangdong Provincial Hospital for Occupational Disease Prevention and Control. Results The numbers of monitored workers were diagnostic radiology 53 674, dental radiology 2 563, nuclear medicine 5 001, radiotherapy 16 687, interventional radiology 22 272 and others 2 087 from 2016 to 2019, of which the number of individuals with doses in excess of investigation level 1.25 mSv, were 76, 6, 18, 28, 133 and 2 respectively. The non-real doses made up 67.1 %, 100 %, 55.6 %, 82.1 %, 76.7 % and 100 % of their respective totals. Their 99th percentile doses P99 were 0.37, 0.39, 0.67, 0.35, 0.54 and 0.30 mSv, and the average periodic dose equivalent were 0.07, 0.06, 0.11, 0.06, 0.07 and 0.05 mSv respectively, indicating a statistically significant difference existing in the average annual effective dose between groups (Z=-26.139—-2.681,P<0.001). Conclusions Due to non-reality of doses in excess of investigation levels and high labor cost, it is suggested to currently use 0.40 mSv per 3 months as investigation level for diagnostic radiology, dental radiology, radiotherapy and others, and 0.70 mSv per 3 months as for nuclear medicine and interventional radiology.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9062877  On-line:0

v
Scan QR Code
&et=539F4EB67C19D566833F4421BA21F105537A1BE0A63F7F6F8ECFEC127A9A4AD32AF616E54A8A0C52C18D8F2F89E22EB8C20BA8B199CAD58C8818CC32C1EA61B5BE61CE75F020B9A021E06C748F4BC0C660CB5B4D0D1C3EB91AD73E87B70C3C44C191789F0D7F72032138B86C3AD39135&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=C76A7301F1A8EE48B0ACC7226B6D47A6&vid=&iid=0B39A22176CE99FB&sid=1F199509C0B6C4D6&eid=76B5E24D6EC46B4B&fileno=20210209&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="C76A7301F1A8EE48B0ACC7226B6D47A6";