Zhou Ning,Deng Lei,Wang Zhe,Wang Jian,Chen Yishui,Liu Yongquan,Deng Jun.Monitoring results of individual doses to medical radiation workers in Jiangxi province from 2014 to 2018[J].Chinese Journal of Radiological Medicine and Protection,2021,41(2):116-121
Monitoring results of individual doses to medical radiation workers in Jiangxi province from 2014 to 2018
Received:October 11, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2021.02.007
KeyWords:Radiological workers  External irradiation  Personal dose  Thermoluminescence
FundProject:江西省卫生健康委科技计划项目(20203871,202131005)
Author NameAffiliationE-mail
Zhou Ning Institute of Occupational Medicine of Jiangxi, Nanchang 330006, China  
Deng Lei Institute of Occupational Medicine of Jiangxi, Nanchang 330006, China  
Wang Zhe Institute of Occupational Medicine of Jiangxi, Nanchang 330006, China  
Wang Jian Institute of Occupational Medicine of Jiangxi, Nanchang 330006, China  
Chen Yishui Institute of Occupational Medicine of Jiangxi, Nanchang 330006, China  
Liu Yongquan Institute of Occupational Medicine of Jiangxi, Nanchang 330006, China jxszfs@163.com 
Deng Jun Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Hits: 2386
Download times: 1007
Abstract::
      Objective To analyze the levels of individual doses to radiation workers receiving medical radiation exposure in hospitals in Jiangxi province, so as to provide reference for radiation protection. Methods The radiation workers of different types in medical institutions in Jiangxi were investigated from 2014 to 2018, involving diagnostic radiology, radiotherapy, nuclear medicine and interventional radiology. Statistical analyses were made of the individual doses to medical radiation workers in the province. Results The total number of monitored workers were 23 833 with average annual individual effective dose of 0.316 mSv. NR1 and NR5, the ratios of the number of workers receiving annual individual doses exceeding 1 and 5 mSv to the total monitored workers were 4.32% and 0.10%, respectively. During the five-year period, the average annual individual effective dose showed a upward and then downward trend, with peak appearing in 2017. A total of 17 909 diagnostic radiologists were monitored, accounting for 75.14% of the total number of monitored workers. The average annual individual effective dose received by workers was 0.329 mSv, the highest, in interventional radiology, followed by diagnostic radiology 0.318 mSv, nuclear medicine 0.283 mSv, and radiotherapy 0.269 mSv, respectively. There were statistically significant differences among radiation workers of different types (χ2=489.39,P<0.001 ). Conclusions The average annual individual effective dose to the radiation workers in medical institutions in Jiangxi province meets the relevant national standards, but with an upward trend in nuclear medicine. The higher levels of individual doses to radiation workers are seen in primary and secondary hospitals. It should be strengthen the oversight of radiation workers in nuclear medicine and in primary and secondary hospitals.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9066718  On-line:0

v
Scan QR Code
&et=3CBA26923B1509143A16FC896CF69571A53CCAB4F5E50EBF618D90FD0CCE9B26045F5ADE528F2655E578C4B6AD43A672231152EF948522348C6BB0D2D3D47EDE69B8BC59AECDA81E4A7A6B7846E60B7907F9BCD502D6C154EAAB0532B0BE17893FA628D1821CCD45E0C59670CC064129&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=C76A7301F1A8EE48F2A05374F8E2038C&vid=&iid=0B39A22176CE99FB&sid=8477411EEDB08A86&eid=CDEBD1ACE0A4C1C1&fileno=20210207&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="C76A7301F1A8EE48F2A05374F8E2038C";