Jiang Ping,Ji Zhe,Jiang Yuliang,et al.Dosimetry evaluation of navigation system-assisted and CT-guided seed implantation in the treatment of recurrent malignant pelvic tumors[J].Chinese Journal of Radiological Medicine and Protection,2021,41(1):50-55
Dosimetry evaluation of navigation system-assisted and CT-guided seed implantation in the treatment of recurrent malignant pelvic tumors
Received:July 24, 2020  Revised:August 27, 2020
DOI:10.3760/cma.j.issn.0254-5098.2021.01.011
KeyWords:Image navigation system  3D-printing template  Radioactive seed implantation  Dosimetry  Recurrent malignant pelvic tumors
FundProject:国家重点研发计划(2019YFB1311300)
Author NameAffiliationE-mail
Jiang Ping Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Ji Zhe Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Jiang Yuliang Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Guo Fuxin Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Sun Haitao Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Wang Junjie Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China junjiewang_edu@sina.cn 
Hits: 3498
Download times: 1580
Abstract::
      Objective To explore the accuracy of CT-guided 125I seed implantation assisted by a navigation system and 3D-printing template in the treatment of recurrent malignant pelvic tumors by comparing pre-plan and intraoperative physical dosimetric parameters.Methods This study involved 15 patients with recurrent malignant pelvic tumors who received CT-guided radioactive 125I seed implantation assisted by a navigation system and 3D-printing template in the Peking University Third Hospital from Dec 2018 to Feb 2020.Seven of the patients had cervical cancers, seven had rectal cancers, and one had prostate cancer.The median age was 55 years (34-84 years old). The prescription dose was 100-150 Gy.The pre-plan and post-implant data were compared, including the number of implanted seeds, implantation needle number, and some dosimetric parameters such as the minimum prescription doses delivered to 90% and 100% of target volume(D90, D100), mean percentages of volume receiving 100%, 150%, and 200% of the prescription doses(V100, V150, and V200), conformity index(CI), external index(EI), and homogeneity index(HI)of the target volume.Results The median lesion volume was 29.20 cm3, the median seed number was 54, and the median D90 was 150 Gy.The post-implant V150 was lower than pre-plan V150 (64.1% vs. 67.1%, t=2.937, P=0.011), and the post-implant mean HI was higher than pre-plan HI (32.01% vs. 26.68%, t=-2.950, P=0.011). There were no significant differences in other dosimetric parameters before and after seed implantation.Conclusions With CT-guided radioactive seed implantation assisted by a navigation system and 3D-printing template in the treatment of recurrent malignant pelvic tumors, the actual postoperative dose could meet the preoperative plan requirement, ensuring the accuracy and consistency of the dose delivered.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029808  On-line:0

v
Scan QR Code
&et=8400690B225D0A446E5501D2BB13B9AA7F198A779A444A616EBEB5F926D3856F8E6A81978308D08DE65217A8404EA2F9C9F890F9F7C4B940B7E910570B4F08C75FBDB86838A4A859C9FFA4D6EA27DF582165B869A528716893AB44DC37BA1F34FDAA12B230EDCFE302907C913027DB662339B28CEBE8471CD237FED692C0371F72E5CB08813F16EE5C3A99DF4F1EA0B0&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=C9B447B97F0B4D9857FE705185831B62&vid=&iid=CA4FD0336C81A37A&sid=771152D1ADC1C0EB&eid=E514EE58E0E50ECF&fileno=20210111&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="C9B447B97F0B4D9857FE705185831B62";