Xu Xuechun,Zhao Fengling,Guo Wei,Wang Huijuan,Lyu Yumin.The 20-year follow-up of five victims externally exposed in “4.26” 60Co radiation accident in Henan province[J].Chinese Journal of Radiological Medicine and Protection,2020,40(8):623-630
The 20-year follow-up of five victims externally exposed in “4.26” 60Co radiation accident in Henan province
Received:February 13, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2020.08.009
KeyWords:Radiation accident  Acute radiation sickness  Late-effect  Medical follow-up
FundProject:山东省重点研发计划(2018GSF118048,2018GSF118006)
Author NameAffiliationE-mail
Xu Xuechun Henan Institute of Occupational Disease Prevention, Zhengzhou 450052, China  
Zhao Fengling Henan Institute of Occupational Disease Prevention, Zhengzhou 450052, China zzzfl1626@126.com 
Guo Wei Henan Institute of Occupational Disease Prevention, Zhengzhou 450052, China  
Wang Huijuan Henan Institute of Occupational Disease Prevention, Zhengzhou 450052, China  
Lyu Yumin Henan Institute of Occupational Disease Prevention, Zhengzhou 450052, China  
Hits: 2234
Download times: 1154
Abstract::
      Objective To investigate the late effects induced by external ionizing radiation through long-term follow-up of the victims exposed to 60Co radiation source at "4.26" accident in Henan in 1999, and to provide valuable experience in the radiological medicine. Methods Medical observations of the clinical symptoms, signs, eye lens examination and previous medical history of the five exposed victims were performed and recorded. The changes of the laboratory routine examinations, immune function, thyroid function, reproductive hormone levels, tumor markers, radiation genetic indicators as well as ultrasound examination of thyroid, cardiac, reproductive system, electrocardiogram, chest CT were systematically reviewed. Results The typical radiation-induced cataract was found in "Mei" 2-3 years after 60Co accidental irradiation. 13 years after irradiation, the cataract surgery and intraocular lens implantation in left eye were performed followed by the same operation in right eye in November 2019. Different degrees phacoscotasmus under the posterior capsule or equatorial part of the eyes were also found in the rest of victims. ECG result of "Mei" indicated myocardial ischemia 7 years after accident. "Tian" confirmed diagnosis coronary heart disease 12 years after irradiation, and the surgery about coronary angiography heart stent implantation was taken at 20 years after irradiation. Five victims showed increased serum total cholesterol and/or triglycerides, and 4 victims showed bilateral or unilateral common carotid atherosclerotic plaque formation. Higher levels of thyroid stimulating hormone (TSH) were observed in "Mei" at 11 years after the irradiation. The thyroglobulin antibody (TGA)and thyroid microsomal antibody (TMA) were obviously increased in "Yi", accompanied by thyroid uneven found by ultrasound. The thyroid nodules in "Mei" and "Min" were observed at 15 years after irradiation. The diagnosis of diffuse large B cell lymphoma(DLBL) in "Tian" was confirmed at 13 years after irradiation. Slightly higher of Neuron-specific enolase(NSE) were found in "Tian", "Min" and "Yi". A small nodule was detected from chest CT of "Tian". Most of the chromosome aberrations observed in peripheral blood lymphocytes from the victims were stable chromosomal aberration such as translocation (t) with a few dicentric chromosome (dic) and acentric fragment (ace) in "Wang" and "Tian". Conclusions Ionizing radiation can cause variable degrees of deterministic effects in lens, thyroid gland and cardiovascular circulatory system and stochastic effects such as neoplasm. The genetic damages will last long in the patients.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9071325  On-line:0

v
Scan QR Code
&et=C2BE70D106C521E64F58359A1F4A1BF7EB1E100ED7F6E7DBA7E5A07730D7306254EDE5DAEDF703B8AFF225702BD7A1AFCD4994460FF8AE78D53601A27DE2E9348DA941577391E188B77818B44DAE955877E849CAFF314E2852CE30329EFDE5B6237003EB66691620C3C64F2CCCDAABA6D55C5F5DD72EA97BC529D6F45EF698BD&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=0D1D160AB8016934&aid=47415C07092E978C4E56E152C7A410D9&vid=&iid=5D311CA918CA9A03&sid=F8AEC975DBDD7F2F&eid=039DCCB9394D9766&fileno=20200809&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="0D1D160AB8016934"; var my_aid="47415C07092E978C4E56E152C7A410D9";