Yuan Xiangkun,Hou Guangying,Zhang Yongxia,Gao Lei,Hu Jianwei,Miao Junjun,Qi Ziwei.Therapeutic effect of different doses of bevacizumab on radiation brain necrosis[J].Chinese Journal of Radiological Medicine and Protection,2019,39(10):768-771
Therapeutic effect of different doses of bevacizumab on radiation brain necrosis
Received:February 18, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.10.010
KeyWords:Bevacizumab  Cerebral radiation necrosis  Radiotherapy
FundProject:科技部NQI项目(2017YFF0206206)
Author NameAffiliationE-mail
Yuan Xiangkun The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China yuanxiangkun@126.com 
Hou Guangying The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China  
Zhang Yongxia The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China  
Gao Lei The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China  
Hu Jianwei The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China  
Miao Junjun The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China  
Qi Ziwei The Second Department of Radiotherapy and Chemotherapy, Hebei Cangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou 061000, China  
Hits: 2214
Download times: 1262
Abstract::
      Objective To evaluate the efficacy and safety of bevacizumab in the treatment of radiation brain necrosis, and to provide guidance for rational clinical application. Methods A retrospective analysis was made of 14 patients with radiation brain necrosis who had failed to receive mannitol and hormone treatment or had been treated for the first time. All the patients were divided into two groups according to different treatment regimens (5.0 mg/kg repeated every 14 d and 7.5 mg/kg repeated every 21 d). The changes of enhanced lesions in MRI T1W1 phase and edema in T2W1 phase were compared separately in the two groups. The clinical symptoms, changes of KPS score and adverse drug reactions were recorded. Results Totally 14 patients completed at least two cycles of treatment. After two cycles of treatment, the KPS scores of both groups were improved. The KPS scores of 5.0 mg/kg group were increased by 31.66 points on average compared with those before treatment. The KPS scores of 7.5 mg/kg group were increased by 27.50 points on average compared with those before treatment. The volume of CRN lesions were decreased(46.0±9.4)%(t=6.57,P<0.05) and the volume of edema lesions decreased(68.9±8.9)%(t=3.32,P<0.05) in 5.0 mg/kg group. In 7.5 mg/kg group, these two parameters were reduced by(53.9±10.7)%(t=7.89,P<0.05 and (77.1±14.3)%(t=4.22,P<0.05), respectively. There was no significant difference in the reduction of the mean volume of CRN lesions and the volume of edema area between the two groups (P>0.05). In this study, the incidence of adverse events in the 5.0 mg/kg group was similar to that in the 7.5 mg/kg group, with no significant difference(P>0.05). Conclusions Bevacizumab can significantly improve the clinical symptoms and quality of life of patients with radiation brain necrosis. The safety of 5.0 mg/kg treatment regimen repeated every 14 d is similar to that of 7.5 mg/kg treatment regimen repeated every 21 d, which can be used for reference in the treatment of CRN.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9073308  On-line:0

v
Scan QR Code
&et=E0F54BF06C7306DCA0DCBD97F46B1913A215D08ED7DFF43A0C1D7BB5637184BC25BD4833F68BDC261026BA56B057B9CE9758D63DE429C6AD3A2ACED0E00BC00CE0F30713B314A0DFB0CEEDF436ADCA2DF26DD77131DA13DB&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CA335AF59099EF4D4E&vid=&iid=F3090AE9B60B7ED1&sid=B5D9C773C430C13C&eid=E3691231514F8E11&fileno=20191010&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CA335AF59099EF4D4E";