Du Yi,Wang Ruoxi,Yue Haizhen,Liu Zhuolun,Zhang Jian,Hu Qiaoqiao,Wu Hao.State of the art of gel dosimeters for three-dimensional radiotherapy dose verification[J].Chinese Journal of Radiological Medicine and Protection,2019,39(7):544-548
State of the art of gel dosimeters for three-dimensional radiotherapy dose verification
Received:November 19, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2019.07.012
KeyWords:Precision radiotherapy  3D dose verification  Gel dosimeters
FundProject:北京市自然科学基金(1184014,1174016);中国博士后科学基金(2017M620542);首都卫生发展科研专项(2018-4-1027);国家自然科学基金(11505012)
Author NameAffiliationE-mail
Du Yi Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China  
Wang Ruoxi Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China  
Yue Haizhen Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China  
Liu Zhuolun Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China  
Zhang Jian Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China  
Hu Qiaoqiao Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China  
Wu Hao Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, China 13552661030@139.com 
Hits: 2872
Download times: 1200
Abstract::
      Dose verification, as part of the radiotherapy QA chain, is a significant method to ensure the patients' safety and efficacy of treatment. The increasing application of precision radiotherapy techniques in clinic has advanced the need of three-dimensional (3D) dose verification. Gel dosimeters, prevailing for its intrinsic 3D high-resolution measurement and good tissue equivalence, can serve as effective supplement to the clinical radiotherapy dosimetric system. This paper reviews the method ology, dose response mechanism, characterizations of the state-of-the-art gel dosimeters. Gel dosimeters, outstanding for 3D dose measurement, have a great potential to explore both for clinical application and academic research.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9057456  On-line:0

v
Scan QR Code
&et=0365EE7BB5C4E8D035BD110BA794D6E09528058B1F767195C4CE8A79941A2ACF36D54D86A44B9A837BC6CC93DE385406F338E39AA2B46FA0D01202E1612861E46F9F2522DE2EFBFAC79B64419C6DB40044910F02D4A185F2&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CA684CDB1B4B82D177&vid=&iid=DF92D298D3FF1E6E&sid=B34BDD6A690A04C0&eid=E5D85F291CED2DA6&fileno=20190712&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CA684CDB1B4B82D177";