Wang Xue,Wang Wei,Li Jianbin,Xu Min,Huo Zongwei,Qiu Pengfei.Target definition for internal mammary lymph node irradiation based on distribution of internal mammary sentinel lymph node developed on SPECT/CT fusion imaging[J].Chinese Journal of Radiological Medicine and Protection,2019,39(7):511-516
Target definition for internal mammary lymph node irradiation based on distribution of internal mammary sentinel lymph node developed on SPECT/CT fusion imaging
Received:January 29, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.07.006
KeyWords:Breast cancer  Internal mammary sentinel lymph node  SPECT/CT  Target volume  Delineation
FundProject:国家自然基金(81703038,81502314);山东省重点研发计划项目(2017GSF18102);山东省自然科学基金(ZR2017PH006);国家重点研发计划项目(2016YFC0904700)
Author NameAffiliationE-mail
Wang Xue School of Medicine and Life Sciences, University of Jinan, Shandong Academy of Medical Sciences, Jinan 250022, China  
Wang Wei Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Li Jianbin Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China lijianbin@msn.com 
Xu Min Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Huo Zongwei Department of Nuclear Medicine, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Qiu Pengfei Department of Breast Surgery, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Hits: 2444
Download times: 1189
Abstract::
      Objective To explore the target definition for internal mammary lymph nodes (IMLNs) irradiation based on the distribution of internal mammary sentinel lymph nodes (IM-SLNs) developing on SPECT/CT fusion imaging. Methods A total of 709 breast cancer patients who underwent preoperative SPECT/CT fusion imaging examination in IM-SLN from 2014 to 2018 were selected. All of the selected patients were first diagnosed and did not receive neoadjuvant treatment before SPECT/CT examination. Finally, totally 97 patients with 136 positive imaging IM-SLNs were included in this study. The clinical target volumes (CTVs) were delineated according to the consensus guidelines from RTOG and DBCG and defined as CTVRTOG and CTVDBCG, respectively. The positional relationship of CTVRTOG, CTVDBCG and IM-SLNs were determined. Results The number of IM-SLNs from the first to fifth intercostal spaces were 55, 40, 33, 6 and 1, respectively. And the number of IM-SLNs in the first three intercostal spaces accounted for 94.85% of the total. The average distance from the edge of CTVRTOG to the centre points and the edges of IM-SLNs were 4.10 mm (95%CI 3.54-4.65 mm) and 6.40 mm (95%CI 5.81-6.98 mm), respectively (t=-30.486,P<0.05). For the CTVDBCG, the average distance was 1.60 mm (95%CI 1.16-2.05 mm) and 3.34 mm (95%CI 2.78-3.89 mm), respectively (t=-16.364,P<0.05). The average distances from the edge of CTV to the centre points and the edge of IM-SLNs for CTVRTOG were all significantly greater than those for CTVDBCG (t=16.640, 19.815, P<0.05). The rate of covering IM-SLN center points for CTVRTOG and CTVDBCG were 18.4% and 60.3%, respectively. In order to cover 90% or 100% of the IM-SLN center points, the edge of CTVRTOG should be expanded by 8 or 15 mm, respectively, and the edge of CTVDBCG should be expanded by 5 or 13 mm, respectively. If the diameter of IM-SLN was assumed as 5 mm, the edge of CTVRTOG needed an expansion of 11 or 17 mm to contain 90% or 100% of IM-SLNs, respectively, while the edge of CTVDBCG needed 7 or 16 mm to cover 90% or 100% of IM-SLNs, respectively. Conclusions It is reasonable to include the first three intercostal spaces IMLNs for prophylactic irradiation based on the distribution of IM-SLNs. However, CTVs based on the two guidelines are both insufficient to cover 90% of IM-SLNs.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9062170  On-line:0

v
Scan QR Code
&et=2585F6697D6651BD219B5FD638D4556A686C91EEE436A5F928C41FE15358132F6C98B28956AA5F2FA8822072460F3617959B0572F286BD9C58F99CB2B8E4F6324B6049C47FB51469A791177649F89978B22E67F7B89B1182CB6B753A001726A925C791737A9A45656D9DA762E3DA38FF1DF71CBB4F27C6E371C6FFBDEE3BFD950586F93EA3DCD1D9873F9A24A3822ABC449CCBF6BD0F4D66CB7A02BA32EE71D0EFF8BEAA531834B2&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CA7F05301314C9352A&vid=&iid=DF92D298D3FF1E6E&sid=B99A53AADE50D922&eid=AF0641F74554D706&fileno=20190706&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CA7F05301314C9352A";