Niu Zhen,Liu Chunxu,Liu Yan,Yang Shoulong,Zhang Jimian.Investigation on the frequency of medical exposure of X-ray diagnostic equipment in Tianjin[J].Chinese Journal of Radiological Medicine and Protection,2019,39(6):450-453
Investigation on the frequency of medical exposure of X-ray diagnostic equipment in Tianjin
Received:January 24, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.06.009
KeyWords:X-ray diagnosis  Medical exposure  Frequency
FundProject:
Author NameAffiliationE-mail
Niu Zhen Institute of Occupational Disease Control and Prevention, Tianjin Center for Disease Control and Prevention, Tianjin 300011, China  
Liu Chunxu Institute of Occupational Disease Control and Prevention, Tianjin Center for Disease Control and Prevention, Tianjin 300011, China  
Liu Yan Institute of Occupational Disease Control and Prevention, Tianjin Center for Disease Control and Prevention, Tianjin 300011, China  
Yang Shoulong Institute of Occupational Disease Control and Prevention, Tianjin Center for Disease Control and Prevention, Tianjin 300011, China  
Zhang Jimian Institute of Occupational Disease Control and Prevention, Tianjin Center for Disease Control and Prevention, Tianjin 300011, China zhangjimian@126.com 
Hits: 3062
Download times: 1439
Abstract::
      Objective To assess the frequency of medical exposure from X-ray diagnostic equipment in Tianjin, and provide recommendations for regulating medical radiation management and rational allocation and use of medical and health resources. Methods Using the census method, questionnaries were issued in the form of an administrative document to investigate the basic information on X-ray diagnostic equipment and medical procedure frequency in 687 hospitals (excluding military and armed police hospitals) in 2018. Mean values of frequencies were derived by dividing the number of procedures for each type of X-ray equipment by the total number of permanent residents. Results There were 1 562 pieces of X-ray diagnostic equipment (including interventional radiology), with an average of 1.00 unit per 10 000 population. There were 4 782 radiation workers engaged with X-ray diagnostic work (including interventional radiology), averaged on 3.06 workers per unit, with the highest of 5.25 workers per unit in tertiary hospitals and the lowest of 1.18 in ungraded hospitals. The city's X-ray diagnostic medical exposure came from 8 905 970 medical procedures, including 54.81% for tertiary hospitals, 18.00% for secondary hospitals, 16.21% for primary hospital, and 10.98% for ungraded hospitals. X-ray photography contributed 71.30% with annual frequency of 407.84 examinations per 1 000 population, CT scans 21.81% with annual frequency of 124.74 examinations per 1 000 population, interventional radiology 1.04%, with annual frequency of 5.98 examinations per 1 000 population, and other types of X-ray examinations 5.85% with annual frequency of 33.47 examinations per 1 000 population. ConclusionsThe configuration of X-ray diagnostic equipment in Tianjin is basically reasonable. The frequency of X-ray diagnostic medical exposure is increasing year by year. The rationality of the distribution of X-ray diagnostic examinations needs to be further improved. To reduce dose to population, for the public health and safety is important issues in the future of radiation protection.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9061327  On-line:0

v
Scan QR Code
&et=9A2B3ECE8B55D590F309F17E6178CC7F857184D70DF599B75FF3CA806227F5EF71041144D45D5CF77CFB544090336927B5E606FB54927204DE06A0102F139513E782CE0FBF976EB3FF1B087BA0C441782D57B7C4612329C391AFB4DE6B0BD650&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CA42A9BB7DF7FDC656&vid=&iid=B31275AF3241DB2D&sid=0A0BD3F594F876C0&eid=FB36B1C076A263FA&fileno=20190609&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CA42A9BB7DF7FDC656";