Tan Huayan,Liu Zhijie,Fu Qingguo,Yang Haiming,Yang Chaofeng,Deng Ye,Luo Tingjun.Application of inverse planning simulated annealing in the treatment of cervical cancer with combined intracavitary and interstitial three-dimensional brachytherapy[J].Chinese Journal of Radiological Medicine and Protection,2019,39(6):428-433
Application of inverse planning simulated annealing in the treatment of cervical cancer with combined intracavitary and interstitial three-dimensional brachytherapy
Received:October 19, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2019.06.005
KeyWords:Cervical cancer  Graphical optimization  Inverse planning simulated annealing  Three-dimensional brachytherapy  Interstitial brachytherapy
FundProject:广西壮族自治区卫生计生委自筹经费科研课题(Z20180624)
Author NameAffiliationE-mail
Tan Huayan Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China  
Liu Zhijie Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China liuzj@sysucc.org.cn 
Fu Qingguo Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China  
Yang Haiming Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China  
Yang Chaofeng Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China  
Deng Ye Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China  
Luo Tingjun Department of Radiation, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, China  
Hits: 2443
Download times: 1402
Abstract::
      Objective To evaluate the effect of an inverse planning simulated annealing (IPSA) in the treatment of cervical cancer with combined intracavitary and interstitial three-dimensional brachytherapy. Methods A total of 60 patients with locally advanced cervical cancer who received both external beam radiotherapy and combined intracavitary and interstitial brachytherapy in our hospital from October 2016 to July 2018 were enrolled. Patients were divided into four groups with 15 patients each according to the number of needles applied (1, 2, 3, and 4 needles, respectively). Dosimetric distributions were optimized with both Graphical optimization (GRO) and IPSA. Paired t-test was applied to compare the dosimetric differences between plans optimized with GRO and IPSA. Results The D90 and V100 of IPSA plans were higher than those of GRO (t=-4.742, -4.823, P<0.05), while the conformity index (CI) and conformal index (COIN) were slightly lower than those of GRO plans (t=9.642, 8.783, P<0.05). No significant difference in the V150, V200, V300 between IPSA and GRO (P>0.05) was observed. There was also no significant difference in the D2 cm3 of bladder and rectum between IPSA and GRO (P>0.05). The difference of D90 between IPSA and GRO was increased as the number of implanted needles increased, which increased from 4 cGy to 14 cGy as the number of needle increased from 1 to 4. The difference of V100 between GRO and IPSA was also increased as the number of needle increased. Conclusions In the treatment of cervical cancer with combined intracavitary and interstitial three-dimensional brachytherapy, IPSA plan could improve the target coverage(D90, V100)without increasing the dose to the OARs and high dose region in the target compared with GRO. With the numbers of needles increased, the advantage of IPSA increased in terms of target coverage.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9060327  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A94527D8C68DFB10B6FF2B7A8C448AEE0AD143FB8790B02E3D66A566B27936ACA08F021ABEBE9C0FF495E3F9D7032842EB99EB41B8146B2D84093CC3D8F616DB2472F89B76D34223EB4507769C50A3852BC2F02B216C190AFC102CFBE719038A0A8574B3894796E6E490556C4A11E02E41B9400C02AFB9E56B993940978E06A6B92F28798A04AB31AA280A7D983F8FCD356F6340F19849CC0186962933579FBBFAE&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=C287CD5914DB95B0E3588AF4CAD84112&vid=&iid=B31275AF3241DB2D&sid=B7ACE2F11789CAE0&eid=DDEED1BDDBFAA8A7&fileno=20190605&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="C287CD5914DB95B0E3588AF4CAD84112";