Zhao Peifeng,Zhou Gang,Sun Yanze,et al.Multileaf collimator shielding technique to reduce cardiac dose in hybrid intensity modulated radiotherapy after breast conserving surgery for left-sided breast cancer[J].Chinese Journal of Radiological Medicine and Protection,2019,39(2):107-112
Multileaf collimator shielding technique to reduce cardiac dose in hybrid intensity modulated radiotherapy after breast conserving surgery for left-sided breast cancer
Received:July 15, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2019.02.005
KeyWords:Breast cancer  Intensity-modulated radiotherapy  Cardiac toxicity  Multileaf collimator  Cardiac shielding
FundProject:
Author NameAffiliationE-mail
Zhao Peifeng Department of Radiotherapy and Oncology, The Second Affiliated Hospital to Soochow University, Institute of Radiotherapy and Oncology, Soochow University, Suzhou 215004, China  
Zhou Gang Department of Radiotherapy and Oncology, The Second Affiliated Hospital to Soochow University, Institute of Radiotherapy and Oncology, Soochow University, Suzhou 215004, China zhougang0626@163.com 
Sun Yanze Department of Radiotherapy and Oncology, The Second Affiliated Hospital to Soochow University, Institute of Radiotherapy and Oncology, Soochow University, Suzhou 215004, China  
Zou Li Department of Radiotherapy and Oncology, The Second Affiliated Hospital to Soochow University, Institute of Radiotherapy and Oncology, Soochow University, Suzhou 215004, China  
Tian Ye Department of Radiotherapy and Oncology, The Second Affiliated Hospital to Soochow University, Institute of Radiotherapy and Oncology, Soochow University, Suzhou 215004, China  
Hits: 4565
Download times: 2108
Abstract::
      Objective To reduce the risk of radiation-induced cardiac injury in patients with left breast cancer after breast-conserving surgery by multileaf collimator (MLC) shielding technique. Methods A total of 18 patients with left breast cancer after breast conserving surgery were selected to obtain 3DCT and 4DCT images at free breathing state. The target area was identified on the 3DCT image by registration with 4DCT images and to develop a hybrid intensity-modulated treatment plan (H_IMRT) and a heart sparing hybrid intensity-modulated treatment plan (HSH_IMRT) to introduce MLC shielding technology to reduce the cardiac exposure dose, and to perform dosimetry verification of the treatment plan by using the Compass verification system. The prescription dose was 50 Gy in 25 fractions. The dosimetry parameters of the target area and the organs at risk were compared between the two treatment plans and the dose verification result. Results The result of the treatment plan showed that compared with H_IMRT, the dose uniformity of the target area of HSH_IMRT was better, and the difference of conformability was not statistically significant(P>0.05). The mean dose of the whole heart decreased by 23.67%(t=13.693,P<0.05) compared with the former. Dmax and Dmean of other substructures of the heart were lower than the former. The result of dose verification showed that there was no statistically significant difference in uniformity and conformity between the two planned target doses(P>0.05). The mean dose of the whole heart of HSH_IMRT was 24.88%(t=13.782,P<0.05) lower than that of H_IMRT, and except for the left ventricle and right ventricle, the Dmax of other heart substructures and Dmean of all heart substructures decreased. Both the planned and the dose verification result showed that the V20 and the Dmean of the affected lung were lower in HSH_IMRT. Conclusions Reasonable introduction of MLC shielding technology in H_IMRT can reduce the exposure dose of cardiac and further reduce the risk of radiation damage in heart.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029149  On-line:0

v
Scan QR Code
&et=EC169CCC165ABEF3630E9E255F1641B63E06C18A5375B440A5C096A7BB00267C31E6971461875BA55AB50CB5E185F265D51765FEA271ED5E4D095422DAA77E390AB2BB7166B620D55DEE7C2EC371A2CEC372AF4E984AD23866EE6B1D76A0C4EE491528FED8CB0B3BB6A11CBF13A1CFB9D734F6F87E6C5BAE489659937DF401FFF6480CE9E62B3353CC1989E86E948F8B8741C7932850B14BFD521500E593D23462F5510BF424C695&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=70F0454B7881B23EE37E55EB95B5118A&vid=&iid=0B39A22176CE99FB&sid=D767283A3B658885&eid=4BB057F167CF3A60&fileno=20190205&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="70F0454B7881B23EE37E55EB95B5118A";