Li Xiaoliang,Su Yinping,Lei Shujie,et al.Analysis of occupational radiation sicknesses diagnosed in China from 2013 to 2017[J].Chinese Journal of Radiological Medicine and Protection,2018,38(10):779-783
Analysis of occupational radiation sicknesses diagnosed in China from 2013 to 2017
Received:May 02, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2018.10.012
KeyWords:Occupational radiation sickness  Radiation worker  Occupational health surveillance
FundProject:
Author NameAffiliationE-mail
Li Xiaoliang Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Su Yinping Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Lei Shujie Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Zhao Xipeng Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Fu Yinghua Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Hao Shuxia Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Liu Jianxiang Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Sun Quanfu Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China sunquanfu@nirp.chinacdc.cn 
Hits: 4927
Download times: 2564
Abstract::
      Objective To analyze the changes in distribution of occupational radiation cases reported from 2013 to 2017 in China and learn about the occupational health risks of radiation workers. Methods Descriptive analyses were made of regional distribution, disease category distribution, occupation category distribution and exposure mode distribution of these cases, according to the reports (2013-2017) of occupational radiation sickness from "Occupational Health of Radiation Workers Management System". Results There were 54 diagnostic radiology agencies for occupational radiation sickness in China that covered all provinces, autonomous regions and municipalities except Tibet and Production and Construction Corps of Xinjiang. A total of 106 new cases were reported from 2013 to 2017. Most of the cases were radiogenic neoplasm (43.40%), and chronic radiation sickness were from external exposure (16.98%) and radiation cataract (16.04%). Most of the cases (70.75%) were engaged in medical application and a small part of the cases (13.21%) engaged in industry application. Chronic exposure (80.19%) was the most frequent form of exposure mode, but acute exposure (5.66%) was very few. A part of cases (14.15%) were reported without exposure mode. Conclusions The morbidity of occupational radiation sickness declined generally in China and occupational health management of key workers should be strengthened continuously.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029185  On-line:0

v
Scan QR Code
&et=6FD48CA0A0DD4759DA21519C9295C92A21E85FFED330C2B8E48B1347C8ED5C9D32916DE5B3F3F83F8B8AC59E4731E76EF34FAF21F02EE0DC3DB2C4D83898158522E51D6A701C80CB2D11B4D214DC62853A60F0AE8985C413&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=EA357AD73C8E13BC&aid=BC4A7A631EF4C49969E2D1AA86C8BA24&vid=&iid=F3090AE9B60B7ED1&sid=EEAFC972BAD75B1F&eid=839A12D3ACF8C715&fileno=20181012&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="EA357AD73C8E13BC"; var my_aid="BC4A7A631EF4C49969E2D1AA86C8BA24";