Yu Ting,Li Jianbin,Wang Wei,Xu Min,Shao Qian,Zhang Yingjie,Liu Xijun.A comparative study of target volumes based on deformation registration using preoperative prone magnetic resonance imaging and postoperative prone computed tomography imaging for patients undergoing breast-conserving surgery[J].Chinese Journal of Radiological Medicine and Protection,2018,38(7):499-504
A comparative study of target volumes based on deformation registration using preoperative prone magnetic resonance imaging and postoperative prone computed tomography imaging for patients undergoing breast-conserving surgery
Received:April 27, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2018.07.004
KeyWords:Preoperative diagnostic magnetic resonance image  Postoperative prone computed tomography simulation image  Deformable image registration  Target volume comparison  External-beam partial breast irradiation
FundProject:国家重点研发计划项目(2016YFC0904700);国家自然基金青年基金(81703038);山东省重点研发计划项目(2017GSF18102);山东省自然科学基金(ZR2017PH006)
Author NameAffiliationE-mail
Yu Ting School of Medicine and Life Sciences, University of Jinan, Shandong Academy of Medical Sciences, Jinan 250022, China  
Li Jianbin Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China lijianbin@msn.com 
Wang Wei Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Xu Min Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Shao Qian Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Zhang Yingjie Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Liu Xijun Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Hits: 3213
Download times: 2044
Abstract::
      Objective To explore the differences and correlation between the target volumes based on deformation registration (DIR) using preoperative prone diagnostic magnetic resonance (MR) imaging and postoperative prone computed tomography (CT) simulation imaging for patients undergoing breast-conserving surgery (BCS). Methods Eighteen breast cancer patients suitable for external-beam partial breast irradiation (EB-PBI) after BCS were enrolled. Preoperative prone diagnostic MR and postoperative prone CT scan sets were acquired during free breathing for all patients. The gross tumor volume (GTV) delineated on the preoperative diagnostic MR images was defined as GTVMRI, the clinical target volumes (CTVMRI+1 and CTVMRI+2) were defined as 10 and 20 mm margins around the GTVMRI, and the planning target volume (PTVMRI+1 and PTVMRI+2) were defined as 15 and 25 mm margins around the GTVMRI,respectively. Tumor bed (TB) delineated on the postoperative prone CT simulation images acquired during free breathing was defined as GTVTB, CTV and PTV were defined as 10 and 15 mm margins around the GTVTB, respectively. The target volume of the whole breast contoured on the MR and CT images were defined as CTVBreast-MRI and CTVBreast-CI, respectively. The MR and CT images were registered deformably in MIM software system. Results The GTVTB, CTVTB and PTVTB were significantly greater than GTVMRI, GTVMRI+1 and PTVMRI+1, respectively (Z=-3.593, -3.593, -2.983, P<0.05). Meanwhile, the CTVTB and PTVTB were significantly less than the CTVMRI+2 and PTVMRI+2,respectively(Z=-2.722, -2.853, P<0.05). The conformal index (CI) and degree of inclusion (DI) of GTVTB-GTVMRI, GTVTB-CTVMRI+1, CTVTB-GTVMRI and CTVTB-GTVMRI+1 based on center-coincidence of the compared targets were better than those based on DIR of the thorax(Z=-3.724、-3.724、-2.591、-3.593, P<0.05;Z=-3.724、-3.724、-3.201、-3.724,P<0.05). Conclusions For the patients enrolled for prone EB-PBI, target volumes delineated on the preoperative prone MR images were significantly smaller compared to that on the postoperative prone CT images, but a statistically significant positive correlation was found between the MR and CT target volumes. There were still relatively poor spatial overlap whether for the whole breast or the targets between the preoperative prone diagnostic MR images and the postoperative prone simulation CT images based on DIR. Therefore, it is infeasible to guide postoperative EB-PBI target delineation using the preoperative prone diagnostic MR images.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9061306  On-line:0

v
Scan QR Code
&et=8E4FC607531F30FE26E3E977424F764A57CE769E54EB0DCD8BB5E8EC59F560F2048F09E7955D385136CBEBEEA56626C20212434DE92DD17CBC05889BC8FDD1D3B7D73F1E4D37E7B077F7A4FDC412F45F9BAA2D242832120E2BB93709CD31B1E5E8E1929D1E8A6E8B685CE4D8A7B7185C2036BF71515980D5033CF4961A0EA1053260D0441C18CAE6018D18A1AE541DC6DAC64C4051F6585130FC4786E1501500AAE49D3D9E05EBCE44CD036D423302B3A61B43BF8584DF9407C71F57A3FBF803B657191D99E43F09445FE2BC69F632765EF87F1144BB3DBF6ABA6DE5C67C9FBCDB2B6ED7A111FA18&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=EA357AD73C8E13BC&aid=415CD46E06B7C80C78F4D3E9F793D7EC&vid=&iid=DF92D298D3FF1E6E&sid=A03A15CF5604A8B0&eid=9B1D77939DDB4B89&fileno=20180704&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="EA357AD73C8E13BC"; var my_aid="415CD46E06B7C80C78F4D3E9F793D7EC";