Huang Rong,Teng Jianjian,Zeng Xiaohong,Chen Mo.Application of active bone marrow defined with single photon emission computed tomography to optimize the intensity modulated radiotherapy plan in cervical cancer after hysterectomy[J].Chinese Journal of Radiological Medicine and Protection,2018,38(6):419-423
Application of active bone marrow defined with single photon emission computed tomography to optimize the intensity modulated radiotherapy plan in cervical cancer after hysterectomy
Received:March 05, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2018.06.004
KeyWords:Cervical neoplasm  Radiotherapy  Intensity-modulated  Single photon emission computed tomography
FundProject:国家重点研发计划项目(2017YFC0113200)
Author NameAffiliation
Huang Rong Department of Radiotherapy, First People's Hospital of Foshan, Foshan 528000, China 
Teng Jianjian Physical Room, First People's Hospital of Foshan, Foshan 528000, China 
Zeng Xiaohong Department of Radiotherapy, First People's Hospital of Foshan, Foshan 528000, China 
Chen Mo Department of Radiotherapy, First People's Hospital of Foshan, Foshan 528000, China 
Hits: 2701
Download times: 1473
Abstract::
      Objective To explore the dosimetric characteristics of single photon emission computed tomography (SPECT) combined with bone marrow sparing intensity modulated radiotherapy in patients with cervical cancer. Methods Twenty patients with cervical cancer after hysterectomy were performed on 99Tc thiocolloid SPECT bone marrow imaging to determine the active bone marrow in the pelvis. SPECT image combined with the simulation CT was used as the primary planning data set. Two plans for bone marrow sparing modulated radiotherapy were generated according to the bone marrow volume defined by SPECT and outline of the pelvis (SPECT-IMRT planning and BMS-IMRT planning). Furthermore, the target section and the dosimetric distribution in organs at risk (bone marrow, small intestine, rectum and bladder) in the two plannings were compared. The prescribed dose to the PTV was 45 Gy. Results The volume of the bone marrow in SPECT-IMRT planning and BMS-IMRT planning was (238.15±36.82) and (1 100.61±109.92) cm3, respectively (t=33.273,P<0.05). The average bone marrow volume of SPECT-IMRT planning in high-dose radiation region (V30, V40 and V45) was decreased by 6.9%, 5.7% and 2.6% respectively compared with BMS-IMRT planning (t=3.540,3.4261,3.448, P<0.05), but there was no statistical significant difference between the two plannings in the dose volume of low-dose radiation (V10 and V20, P>0.05). The PTV coverage rate and exposure dose of other organs at risk (small intestine, rectum and bladder) in the two plannings were not significantly different (P>0.05). Conclusions SPECT bone marrow imaging could clearly show the range of active bone marrow on CT scan images. Compared with BMS-IMRT, SPECT-IMRT could further reduce the dose volume of high-dose radiation (V30, V40 and V45). Yet the clinical significance of this advantage also needs to be confirmed by large-scale clinical studies.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9056933  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A94A5657E2362FE04B14D2C669D49E16C4FDDBC01372272129D38BE563C0D1B2356F6BCAD591F9C8F53561CD7813E7EB28D590BCE6CB4A40DEEE63A3D7CDC9D46A362771230A94D25E19CEE65AE5AF43A8C0F6A8EEBD805D6BEA278E839D8E6755C7D48FBD6320328C191F127C72ED8DF6EA32E7B3465A82E649162A7BF98A423CD4CAEDC6591321D5A637EAFE3244038E515F9DCD393F01DCC4F676B376D10500AB3BC491E2BB7FB667CEC820971E4EA90&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=EA357AD73C8E13BC&aid=415CD46E06B7C80C7E8307BC834C7C3A&vid=&iid=B31275AF3241DB2D&sid=A4E67967A1AB25F0&eid=F27A401E323B6FAD&fileno=20180604&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="EA357AD73C8E13BC"; var my_aid="415CD46E06B7C80C7E8307BC834C7C3A";