Wang Lu,Yu Chunfeng,Huang Yanfei,Chai Yun,Wang Jiahao.Target setup margin and dose evaluation for cervical cancer cases based on the off-line adaptive radiotherapy[J].Chinese Journal of Radiological Medicine and Protection,2017,37(12):902-905,910
Target setup margin and dose evaluation for cervical cancer cases based on the off-line adaptive radiotherapy
Received:June 25, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.12.004
KeyWords:Off-line adaptive radiation therapy  Cervical cancer  Target setup margin  Dose evaluation
FundProject:
Author NameAffiliationE-mail
Wang Lu Department of Gynaecology and Obstetrics, Hangzhou Women's Hospital, Hangzhou 310000, China  
Yu Chunfeng Department of Gynaecology and Obstetrics, Hangzhou Women's Hospital, Hangzhou 310000, China  
Huang Yanfei Department of Gynaecology and Obstetrics, Hangzhou Women's Hospital, Hangzhou 310000, China  
Chai Yun Department of Gynaecology and Obstetrics, Hangzhou Women's Hospital, Hangzhou 310000, China  
Wang Jiahao Department of Radiation Oncology, Hangzhou Cancer Hospital, Hangzhou 310000, China wangjiahao1228@Foxmail.com 
Hits: 2622
Download times: 2018
Abstract::
      Objective To study the target setup margin and dose evaluation for cervical cancer patients with volume-modulated arc therapy in the off-line adaptive radiation therapy (off-line ART), Methods A total of fifty patients with cervical cancer were randomly divided into test group and control group. Cone beam CT scanning was performed twice a week, the setup errors in directions of LR, AP and CC were recorded in the whole treatment process. The target setup formula was used to calculate the new CTV-PTV setup margin. At the same time, the setup error was returned to planning isocenter (ISO). For the control group, the dose was recalculated on the basis of the original PTV after considering ISO shift. For the test group, the dose was also recalculated after the new extended boundary of the target. The dosimetric parameters of CTV and organs at risk (OAR) were evaluated between two groups after dose recalculation. Results According to the target setup formula, extended boundaries of CTV in the direction of LR, AP, CC were 0.45, 0.46 and 0.82 cm, respectively. The test group increased in CTV with D100% and D95% (t=-8.16, -6.73, P<0.05) and decreased in femoral head with V40, V30 and Dmean (t=3.14, -9.52, -7.48, P<0.05) than the control group. The test group decreased in the pelvis with V34 and Dmean than control group (t=10.14, -9.38, P<0.05). Conclusions The CTV-PTV setup margin and the dose of OAR were effectively reduced, and the coverage of target area was extended when the off-line ART technology was conducted in the volume-modulated arc therapy for cervical cancer.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069573  On-line:0

v
Scan QR Code
&et=9EF00E663CA39E2F0A0E895E9B40A82996AE606F39E713D81141570F446E36A4AFC016CB405BC4EF945C5690B684AA5A066C92541A836D4C2BA358267F468DC304A36EB6839B5D472D6D1AEB6EAA2F9C696889DE83A0C53787F1D8D17E8B3DE3CBCA5B3D94E688C72C258F45025949EF&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=58EC03D86D1FF9205A6B752392AE44B6&vid=&iid=59906B3B2830C2C5&sid=F52FA2254444BE97&eid=44DABE664F9FA3E4&fileno=20171204&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="58EC03D86D1FF9205A6B752392AE44B6";