Li Chengqiang,Lu Jie,Tao Cheng,Zhu Jian,Duan Jinghao,Yin Yong.Analysis of DVH variations based on interquartile range among IMRT plans[J].Chinese Journal of Radiological Medicine and Protection,2017,37(10):742-746
Analysis of DVH variations based on interquartile range among IMRT plans
Received:May 01, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.10.004
KeyWords:Intensity modulated radiotherapy  Interquartile range of volume  Dose volume histogram
FundProject:国家自然科学基金(81472811,81671785);中国博士后科学基金(2016T90412);山东省科技发展计划项目(2014GSF118011)
Author NameAffiliationE-mail
Li Chengqiang Department of Radiation Oncology Physics, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Lu Jie Department of Radiation Oncology Physics, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Tao Cheng Department of Radiation Oncology Physics, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Zhu Jian Department of Radiation Oncology Physics, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Duan Jinghao Department of Radiation Oncology Physics, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China  
Yin Yong Department of Radiation Oncology Physics, Shandong Cancer Hospital Affiliated to Shandong University, Jinan 250117, China yongyinsd@163.com 
Hits: 3172
Download times: 2469
Abstract::
      Objective To study the dose volume histogram (DVH) difference of target and organs at risk in intensity-modulated radiation therapy(IMRT) planning of cervical cancer based on the interquartile range.Method A total of 22 cervical cancer patients' IMRT plans were retrospectively analyzed. Five groups of DVH curves of PTV and OARs (bladder, rectum, left and right femoral heads) were derived from the Pinnacle3 planning system. The mean DVH curves and interquartile range of volume (IQRvol) as a function of dose were calculated from each group's DVH curve.Results The maximum volume variation for PTV reached at IQRvol (54.03 Gy)=6.95%, the volume of the target reached by the prescription dose was (96.43±1.63)%.The maximum volume variation for bladder reached at IQRvol (17.24 Gy)=14.62%. V40 and V30 for bladder were (32.79±7.06)% and (56.47±9.94)%, respectively. Rectal DVH showed the largest difference at 35.92 Gy, with the quartile of 19.94%, the V40 and V30 for rectum were (30.17±10.80)% and (58.16±11.99)%, respectively. The difference in the bladder and the rectum was statistically significant (z=-6.59, P<0.05). The maximum volume variation of left femoral head reached at IQRvol(16.06 Gy)=31.47%. The maximum volume variation of right femoral head was reached at IQRvol(17.47 Gy)=32.82%. There was no significant difference in IQRvol between right and left femoral head (P>0.05).Conclusions Quartile range curve of DVHs can be used to analyze the deviations of DVH curves of PTV and OARs, and provide guidance for automatic planning optimization parameter setting.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9093106  On-line:0

v
Scan QR Code
&et=6FD48CA0A0DD47593D7E7770C4886B4A61E9712F278690DAC56388054BBBBECC449A4A410470C7B6550EFFA7CA322DB0ABA0AA8581E1BE7F7E840CAF5973A7A1E4DDB4B082B2920D3F8508DCA5E12D38&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=CF1332E5A7C16DE72CC6FA95527C484D&vid=&iid=F3090AE9B60B7ED1&sid=81D76BB45305F8B7&eid=4C49EFA0A53C9DF0&fileno=20171004&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="CF1332E5A7C16DE72CC6FA95527C484D";