Zhao Sanhu,Wu Shouming,Zhao Yaoxian,Yu Shunfei,Luo Jin,Li Yihua,Li Xinxing,Xuan Zhiqiang.Investigation of radiological protection status and radiation exposure level at interventional workplace in Zhejiang province[J].Chinese Journal of Radiological Medicine and Protection,2017,37(8):605-608
Investigation of radiological protection status and radiation exposure level at interventional workplace in Zhejiang province
Received:January 05, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.08.009
KeyWords:Interventional radiology workers  Radiation dose  Protection
FundProject:
Author NameAffiliationE-mail
Zhao Sanhu Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Wu Shouming Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Zhao Yaoxian Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Yu Shunfei Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Luo Jin Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Li Yihua Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Li Xinxing Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China  
Xuan Zhiqiang Division of Radiation and Nuclear Safety, Zhejiang Provincial Center for Disease Control and Prevention 310058 Hangzhou, China 532129014@qq.com 
Hits: 3380
Download times: 2206
Abstract::
      Objective To explore the current status of radiation protection in interventional procedure and to analyze the existent problems. Methods Using the random sampling, 70 interventional radiology workplaces were selected from Hangzhou, Ningbo, Wenzhou, Shaoxing and Jinhua. Information on personal radiation protective products and equipment was collected by filling out the form by hospital and the radiation dose was monitored at various body parts of the workers and at the outside of the operating room. Results All hospitals have been equipped with personal radiation protective products and equipment, 22 of which were not with these products and equipment as required. Chest, abdomen and lower limb of interventional radiology workers are easy to receive higher radiation dose than in head (F=4.85,4.92,P<0.05). The acceptance rates among different body parts of the workers were difference significantly (χ2=35.14,14.92, P<0.05). Using protective curtain can reduce the radiation dose significantly (t=11.61-68.28,P<0.05). Meanwhile, it also can improve the acceptance rates significantly (χ2=6.09-28.45,P<0.05). Conclusions It is necessary to strengthen the use of radiation protection equipment among interventional radiology workers to reduce the levels of the individual doses to them.Hospitals must enhance the routine monitoring for improved radiaton protection.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9059782  On-line:0

v
Scan QR Code
&et=9A2B3ECE8B55D590E6E355423D82FAFD108AB4A379D77DC5CB24AB197FEA72F46136C498051E146791656A8A8C44FC42A57CA4DC2DB381BF87A23C63493AF662402CBB0F17BD1A30AF4350404AFB5D269AB8D0A742C1F6149ACB8777C74C4856446AE749A9D9CE1767705642B1F33E77F6A1258885F323AD30591FAE53C20248&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=3C3EF3B75913B4FF7F9B6824B8F7AC5C&vid=&iid=5D311CA918CA9A03&sid=10A39635766FF5D0&eid=C7B13290323C226E&fileno=20170809&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="3C3EF3B75913B4FF7F9B6824B8F7AC5C";