Pan Tianfan,Lu Jian,Wang Yong,Guo Jinhe.Research progress of 125Ⅰ radioactive seed interstitial brachytherapy in the treatment for pelvic malignancies[J].Chinese Journal of Radiological Medicine and Protection,2017,37(7):557-561
Research progress of 125Ⅰ radioactive seed interstitial brachytherapy in the treatment for pelvic malignancies
Received:April 26, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.07.016
KeyWords:125  Brachytherapy  Pelvic malignancies  Radiation treatment planning  Three dimensional printing
FundProject:国家自然科学基金(81471762);江苏省省级重点研发专项资金(BE2016783)
Author NameAffiliationE-mail
Pan Tianfan Department of Interventional Radiology and Vascular Surgery, Zhongda Hospital, Medical School of Southeast University, Nanjing 210009, China  
Lu Jian Department of Interventional Radiology and Vascular Surgery, Zhongda Hospital, Medical School of Southeast University, Nanjing 210009, China  
Wang Yong Department of Interventional Radiology and Vascular Surgery, Zhongda Hospital, Medical School of Southeast University, Nanjing 210009, China  
Guo Jinhe Department of Interventional Radiology and Vascular Surgery, Zhongda Hospital, Medical School of Southeast University, Nanjing 210009, China jinheguo@sina.com 
Hits: 2401
Download times: 2096
Abstract::
      Brachytherapy with 125Ⅰ radioactive seed has the advantages of low dose-rate,comtinuous irradiation and repeated implantation to inhibit the replication of tumor cells, and the repeatable implantation. It has been widely used in the treatment for cervial cancer, and can also be applied to pelvic malignancies, including ovarian cancer, colorectal cancer, bladder cancer. Compared with external beam radiotherapy, it can improve the dose of target region to control tumor effectively. At the same time,it can protect the normal tissues and reduce the occurrence of complications. In this paper, we summarized the specialty, function mechanism, complications and application status of radioactive 125Ⅰ seed interstitial implantation in the treatment of pelvic malignancies. The application of three dimensional printing in brachytherapy with radioactive 125Ⅰ seed was also introduced.This review can provide a reliable basis for future standardized seed implantation treatment for pelvic malignancies.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9066784  On-line:0

v
Scan QR Code
&et=FC9DA7BF2F842A3BAE24B54F70914FE64102972600D5A980A76A0DFA357D7D1EA9E8BE17BE97CC5741F7FF4F0822FD22A52BE00DFE34E6443B7EAB2D710C8570CF90DEDEEF374BB2FF3F0E22C019EACF6D27401E35A822E325EBA842CC314B1B3C105ECD5E5374E7CDAF489F65A11608C895F839C16BA2E0CFE902E6A4592397&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=BF88AFC87C5C19B46009A7EBAB1F4FB3&vid=&iid=DF92D298D3FF1E6E&sid=2E15A588990CC690&eid=B4F9D541F855CF96&fileno=20170716&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="BF88AFC87C5C19B46009A7EBAB1F4FB3";