Ji Zhe,Jiang Yuliang,Guo Fuxin,Sun Haitao,Fan Jinghong,Zhang Lujing,Wang Junjie.Dosimetry verification of radioactive seed implantation for malignant tumor assisted by 3D printing individual guide template[J].Chinese Journal of Radiological Medicine and Protection,2016,36(9):662-666
Dosimetry verification of radioactive seed implantation for malignant tumor assisted by 3D printing individual guide template
Received:March 19, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2016.09.005
KeyWords:3D printing  Radioactive seed implantation  Dosimetry  Cancer
FundProject:首都临床特色应用研究与成果推广科研项目(Z151100004015171)
Author NameAffiliationE-mail
Ji Zhe Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Jiang Yuliang Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Guo Fuxin Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Sun Haitao Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Fan Jinghong Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Zhang Lujing Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Wang Junjie Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China junjiewang_edu@sina.cn 
Hits: 3869
Download times: 2725
Abstract::
      Objective To compare the dose distribution of postoperative plans with preoperative plans for 3D printing guide template assist radioactive seeds implantations, and explore the accuracy of treatment at dosimetry level. Methods A total of fourteen patients registered from Dec 2015 to Mar 2016 who were applied with 3D printing guide template assisted radioactive seed implantations in the hospital were included in this study. The preoperative planning design and 3D printing template production were performed for all patients. The dose related parameters including D90%, minimum peripheral dose (MPD), V100%, V150%, V200%, conformal index (CI), external index (EI), and homogeneity index (HI) were compared between pre- and post-operation. The paired t-test was used to perform the statistical analysis. Results A total of fourteen 3D printing individual templates were produced which included 16 treatment areas. Compared with preoperative plans, the mean value of V100%, D90% and V150% decreased while the mean value of V200% and MPD increased in postoperative plans. However, there was no significant difference between the two groups except for V100% (t=2.451, P<0.05). The differences of CI, EI, HI between two groups were not statistically significant (P>0.05). Conclusions The validation of actual dose distribution in postoperation assistied by 3D printing template in seed implantation shows that most of parameters could meet the expectation of preoperative plans, which indicates the improvement in accuracy for this new type of treatment.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9063591  On-line:0

v
Scan QR Code
&et=8400690B225D0A4443FBBC25B7F89184BB82AD6AFA2F289F511DBD93BA655F0C07C2C97AA108405CC484E07D34616E6C6425DAFC209420DEE3E31547C7FA004A931998465557A46613DF77748AD841DBA681D4417BA646151E8EEE3D987396A3703F03635A37515E329DE93716F94A120717CA9520320821C97408921D26135C&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9F915C6F01DE79C5&aid=05936A0FD5645515B4E1FF76CDD840CB&vid=&iid=9CF7A0430CBB2DFD&sid=A0C7970CD30381EA&eid=1C3BB0F444F5E427&fileno=20160905&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9F915C6F01DE79C5"; var my_aid="05936A0FD5645515B4E1FF76CDD840CB";