Li Aijing,Song Aiqin,Pan Yuning,Zheng Jianjun.Application of low-tube-voltage combined with adaptive iterative reconstruction in lower extremity computed tomography angiography[J].Chinese Journal of Radiological Medicine and Protection,2016,36(6):465-469
Application of low-tube-voltage combined with adaptive iterative reconstruction in lower extremity computed tomography angiography
Received:November 12, 2015  
DOI:10.3760/cma.j.issn.0254-5098.2016.06.014
KeyWords:Lower extremity  Iterative reconstruction  Computed tomography angiography  Radiation dose  Image noise
FundProject:
Author NameAffiliationE-mail
Li Aijing Department of Radiology, Ningbo No.  
Song Aiqin Hospital, Ningbo 315010, China  
Pan Yuning Department of Radiology, Ningbo First Hospital, Ningbo 315010, China  
Zheng Jianjun Department of Radiology, Ningbo No. zhjjnb2@163.com 
Hits: 2423
Download times: 2404
Abstract::
      Objective To investigate the feasibility of low-tube-voltage in combination with the three-dimensional adaptive iterative dose reduction (AIDR-3D) algorithm in performing lower extremity computed tomography angiography (CTA). Methods A total of 60 patients suspicious of lower extremity arterial occlusion were randomized into control group (120 kV,n=30) and experimental group (100 kV,n=30). The CTA was undertaken with a 320-row scanner (Toshiba Aquilion ONE), and the images was reconstructed with filtered back projection (FBP) algorithm in control group and FBP as well as the AIDR-3D algorithm in experimental group. The subjective image quality, vascular density (VD), noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and dose length product (DLP) were compared between two groups. Results The DLP was significantly lower in experimental group than that in control group[(503.5±104.7) vs. (1099.4±151.7) mGy·cm, t=15.7, P<0.05]. The images in experimental group with 100 kV and FBP protocol had significantly increased VD and noise (t=-3.13,-3.61, P<0.05) than that in the control. The images in experimental group with AIDR-3D had significantly lower noise and higher SNR and CNR than that with FBP (t=13.59, 2.14,P<0.05), also significantly lower noise and significantly higher VD, SNR, and CNR than that in the control (t=-3.75, -4.19, -4.15,P<0.05). Conclusions Low-tube-voltage (100 kV) combined with AIDR-3D reconstruction could significantly improve the image quality and reduce radiation dose in lower extremity CTA with a 320-row CT scanner. Trial registration Chinese clinical trial registry, ChiCTR-DPD-16008054.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9067209  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A94C55E28EAB50CCB29E13F7FDD6397A5D45EBE205FB4CE184D609A99FC68EA40DBAFF2C00119E9F36F8053DFB242421D255A21BA9711B7D2E2146191A39EADC5CCEE0831246E6F5D0EA415BF839F3D23C788C037D010014B818B359774B51CDDE6C80CF52F11F750F7A3CC9A41C31D685A53C11410CAA2E3CA4DD07E37D1E7E3A5&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9F915C6F01DE79C5&aid=D3E0C87FB6A41B560DF90D830F331020&vid=&iid=B31275AF3241DB2D&sid=BC88D6B0750E09D1&eid=8F2250DA83AF77B8&fileno=20160614&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9F915C6F01DE79C5"; var my_aid="D3E0C87FB6A41B560DF90D830F331020";