Chen Zhangfan,Zhao Xinchun,Zhang Huimin,et al.Investigation on entrance surface doses to patients from medical X-ray diagnosis in Guangxi[J].Chinese Journal of Radiological Medicine and Protection,2016,36(4):298-302
Investigation on entrance surface doses to patients from medical X-ray diagnosis in Guangxi
Received:August 04, 2015  
DOI:10.3760/cma.j.issn.0254-5098.2016.04.014
KeyWords:X-ray diagnosis  Entrance surface dose  Digital radiography  Computed radiography  Medical exposure
FundProject:卫生行业科研专项(201002009);广西自然科学基金(2014GXNSFAA118223)
Author NameAffiliationE-mail
Chen Zhangfan Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Zhao Xinchun Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Zhang Huimin Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Tang Mengjian Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Liang Ting Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Chen Faxiang Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Dong Ying Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Ma Yilong Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Qin Zhiying Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China  
Xie Ping Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China gxcdcxp@126.com 
Hits: 5311
Download times: 2884
Abstract::
      Objective To investigate the entrance surface doses to the patients undergoing diagnostic X-ray examinations in Guangxi. Methods A total of 2236 patients who have received diagnostic X-ray examinations were investigated at 25 randomly selected hospitals at different levels where dthermoluminescence dosimeters were used to measure the entrance surface doses in different hospitals with different equipment and different positions. Results The entrance surface dose from X-ray imaging, computed radiography (CR) and digital radiography (DR) were in the range of 0.08-31.51, 0.11-4.25 and 0.05-35.63 mGy, respectively. The entrance doses to abdomen (AP), pelvis (AP), head (LAT), head (PA), chest (PA), chest (LAT), thoracic vertebra (AP), thoracic vertebra (LAT), lumbar vertebra (AP), lumbar vertebra (LAT) were 0.08-19.53, 0.15-18.78, 0.08-9.87, 0.06-9.24, 0.05-2.71, 0.13-2.93, 0.15-19.01, 0.07-25.33, 0.16-27.23, and 0.11-35.63 mGy, respectively. Conclusions The average dose to patients from X-ray diagnosis in Guangxi was in accordance with the relevant standards, but DR could partly lead the chest (PA) dose to exceed the guidance levels of medical exposure.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565539  On-line:0

v
Scan QR Code
&et=9A2B3ECE8B55D590F309F17E6178CC7FB20D5373D9BFEDA850C291A8E9A9AE5ECA259E4644D3603761CEEFC5DCEF961067F43FA697220CAE0193C71480D18F1DE80FB8B7E920EED45FA0D3EBD1066E986884C6FD140CF705AF9A6CE8CA1911EC&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9F915C6F01DE79C5&aid=28B2676AB082C1DC514D7E7936EDEE25&vid=&iid=E158A972A605785F&sid=88D36036CFF69B3C&eid=119B6C0AA09DE6B9&fileno=20160414&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9F915C6F01DE79C5"; var my_aid="28B2676AB082C1DC514D7E7936EDEE25";