Chen Zhangfan,Zhao Xinchun,Zhang Huimin,et al.Investigation on entrance surface doses to patients from medical X-ray diagnosis in Guangxi[J].Chinese Journal of Radiological Medicine and Protection,2016,36(4):298-302 |
Investigation on entrance surface doses to patients from medical X-ray diagnosis in Guangxi |
Received:August 04, 2015 |
DOI:10.3760/cma.j.issn.0254-5098.2016.04.014 |
KeyWords:X-ray diagnosis Entrance surface dose Digital radiography Computed radiography Medical exposure |
FundProject:卫生行业科研专项(201002009);广西自然科学基金(2014GXNSFAA118223) |
Author Name | Affiliation | E-mail | Chen Zhangfan | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Zhao Xinchun | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Zhang Huimin | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Tang Mengjian | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Liang Ting | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Chen Faxiang | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Dong Ying | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Ma Yilong | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Qin Zhiying | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | | Xie Ping | Radiation Hygiene Protection Institute, Center for Disease Prevention and Control, Guangxi Zhuang Autonomous Region, Nanning 530028, China | gxcdcxp@126.com |
|
Hits: 5311 |
Download times: 2884 |
Abstract:: |
Objective To investigate the entrance surface doses to the patients undergoing diagnostic X-ray examinations in Guangxi. Methods A total of 2236 patients who have received diagnostic X-ray examinations were investigated at 25 randomly selected hospitals at different levels where dthermoluminescence dosimeters were used to measure the entrance surface doses in different hospitals with different equipment and different positions. Results The entrance surface dose from X-ray imaging, computed radiography (CR) and digital radiography (DR) were in the range of 0.08-31.51, 0.11-4.25 and 0.05-35.63 mGy, respectively. The entrance doses to abdomen (AP), pelvis (AP), head (LAT), head (PA), chest (PA), chest (LAT), thoracic vertebra (AP), thoracic vertebra (LAT), lumbar vertebra (AP), lumbar vertebra (LAT) were 0.08-19.53, 0.15-18.78, 0.08-9.87, 0.06-9.24, 0.05-2.71, 0.13-2.93, 0.15-19.01, 0.07-25.33, 0.16-27.23, and 0.11-35.63 mGy, respectively. Conclusions The average dose to patients from X-ray diagnosis in Guangxi was in accordance with the relevant standards, but DR could partly lead the chest (PA) dose to exceed the guidance levels of medical exposure. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|