Liu Yufei,Wang Furu,Yu Ningle,et al.Risk analysis of malignant tumor among medical diagnostic X-ray workers during 1997-2011 in Jiangsu province[J].Chinese Journal of Radiological Medicine and Protection,2015,35(6):455-460
Risk analysis of malignant tumor among medical diagnostic X-ray workers during 1997-2011 in Jiangsu province
Received:March 09, 2015  
DOI:10.3760/cma.j.issn.0254-5098.2015.06.012
KeyWords:Medical X-ray workers  Malignant tumor  Radiation carcinogenesis
FundProject:卫生行业科研专项(201002009)
Author NameAffiliationE-mail
Liu Yufei Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Centre for Disease Control and Prevention, Bejing 100088, China  
Wang Furu 江苏省疾病预防控制中心  
Yu Ningle 江苏省疾病预防控制中心  
Xu Xiaosan 江苏省疾病预防控制中心  
Cheng Xiaoqing Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Centre for Disease Control and Prevention, Bejing 100088, China  
Fu Yinghua Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Centre for Disease Control and Prevention, Bejing 100088, China  
Sun Quanfu Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Centre for Disease Control and Prevention, Bejing 100088, China qfusun@nirp.cn 
Hits: 3467
Download times: 2841
Abstract::
      Objective To continue following up the cohort members in Jiangsu province who were the largest subgroup in Chinese medical X-ray workers cohort subgroups on radiation carcinogenesis and analysis the cancer risk of medical X-ray workers which might be induced by chronic low-dose ionizing radiation between 1997 and 2011. Methods A retrospective cohort study was utilized to accumulate data. Epicure was applied to compute cumulative person years (with module of Datab) and relative risk(including 95%CI) of malignant tumor on exposed group(with module of AMFIT) while the factors such as sex and attained-age were adjusted in the cohort members. Results The 7 708 follow-up members included 3 668 medical X-ray workers. The cumulative person-year in the cohort members was 94 651.2 (1997-2011) and its lost rate was 5.79%. During the follow-up period, 441 cases had became cancer patients. The relative risk of all cancers was 1.44(95%CI:1.18-1.75), so was the solid cancers. Significant elevated risks of cancer were found on lung (RR=1.95, 95%CI:1.30-2.92), esophagus(RR=3.04, 95%CI:1.20-7.70), lymphoma(RR=2.24, 95%CI:0.67-7.48), leukemia(RR=1.57, 95%CI:0.33-7.39),throat(RR=2.47) and thyroid (RR=2.80,95%CI:0.24-32.26) among medical X-ray workers. However, The RR of malignant tumors might not be associated with occupational exposure to ionizing radiation if we considered the lost factors (RR=1.2, 95%CI: 0.94-1.46) Conclusions The RR of malignant tumors such as the cancer on lung, esophagus, thyroid among the medical X-ray workers in Jiangsu province were enhanced which might be associated with occupational exposure to ionizing radiation.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565709  On-line:0

v
Scan QR Code
&et=07BD74647F8C94855A0BBE86A7A3BE9C24B5A7936BCC4BC24C46DAF9E7B9D6219F6C197A0863F8A1F7222AA05B143F05EBA1A5BE8D89E15E322A733B3CCC7D5299989A503831575C34838D0D8476318576C346A7F91336BEBC1013AB8B3D97BB773AE97C7B0AB1B92D8946E82E2E27C1&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FFD10F7019FAA9EC&aid=5F7737E5A04D36C7CDE328CA38CFBA73&vid=&iid=B31275AF3241DB2D&sid=366B1248A15658C5&eid=E0172F1A638CE984&fileno=20150612&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FFD10F7019FAA9EC"; var my_aid="5F7737E5A04D36C7CDE328CA38CFBA73";