Li Jie,Yao Xiaowei,Li Bo,et al.A randomized controlled study on improving the repeatability of setup in postoperative radiotherapy for head and neck cancers through neck muscle group exercise[J].Chinese Journal of Radiological Medicine and Protection,2025,45(10):979-985
A randomized controlled study on improving the repeatability of setup in postoperative radiotherapy for head and neck cancers through neck muscle group exercise
Received:September 18, 2024  
DOI:10.3760/cma.j.cn112271-20240918-00357
KeyWords:Neck muscle group exercise  Head and neck cancer  Radiotherapy  Setup error
FundProject:
Author NameAffiliationE-mail
Li Jie Department of Radiation Oncology, First Affiliated Hospital, Air Force Medical University, Xi'an 710032, China  
Yao Xiaowei Department of Radiation Oncology, First Affiliated Hospital, Air Force Medical University, Xi'an 710032, China  
Li Bo Department of Radiation Oncology, First Affiliated Hospital, Air Force Medical University, Xi'an 710032, China  
Xu Linlin Department of Radiation Oncology, First Affiliated Hospital, Air Force Medical University, Xi'an 710032, China  
Xu Zhaodi Department of Rehabilitation Physiotherapy, First Affiliated Hospital, Air Force Military Medical University, Xi'an 710032, China  
Zhang Lihua Department of Radiation Oncology, First Affiliated Hospital, Air Force Medical University, Xi'an 710032, China  
Bai Fei Department of Radiation Oncology, First Affiliated Hospital, Air Force Medical University, Xi'an 710032, China baifei0912@163.com 
Hits: 3460
Download times: 604
Abstract::
      Objective To explore the effect of neck muscle group exercise on setup errors in postoperative radiotherapy for head and neck cancers. Methods A total of 126 head and neck cancer patients scheduled for radiotherapy at the First Affiliated Hospital, Air Force Medical University from February 2021 to October 2022 were prospectively enrolled. Among these patients, four patients discontinued treatment due to personal reasons, and the remaining 126 patients were randomly divided into an experimental group and a control group, with 61 patients in each group. The experimental group received neck muscle group exercise, while the control group received routine treatment without intervention. Cone-beam CT (CBCT) scans were performed weekly to measure setup errors at the levels of the clivus and the 4th and 7th cervical vertebrae (C4 and C7, respectively). Three-dimensional displacement, systematic errors, and random errors were calculated for each level. The appropriate margins of planning target volumes (PTVs) were determined using the Van Herk formula. Results Baseline characteristics were well-balanced between the two groups, with no statistically significant differences (P > 0.05). Compared to the control group, the experimental group showed significantly smaller setup errors in the left-right (x) and anterior-posterior (z) directions at the clivus level, as well as in the z direction at the C4 and C7 vertebral levels (t = 2.30, 5.29, 4.07, 2.40, P < 0.05). The required PTV margin in the z direction increased to 4.0 mm at C7 from 2.4 mm and 2.8 mm at the clivus in the experimental and control groups, respectively. Correlation analysis revealed a strong negative correlation between the x-direction at the clivus and C4 vertebral levels and the couch angle (RTN) among all patients (r = -0.548, -0.452, P < 0.001). A moderate negative correlation was observed between the inferior-superior (y) direction and the z-direction at the C4 and C7 vertebral levels (r = -0.160, -0.222, P < 0.001). Conclusions Neck muscle group exercise can reduce setup errors and PTV margins in the anterior-posterior direction in postoperative radiotherapy for head and neck cancer patients.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:17878170  On-line:0

v
Scan QR Code
&et=3931F69C5BAC493DD2B27F9CEA6000136AC0DC625B39C60FFE46E848F02AD82305352F52F32EA23C1EC93C8ADDCC78E124C3A166FBF3A95BD401F37DCDF0FD38B211B4D93DD4D88D7F21F5081F0D1C5502800C69F0A9A8AD4AB3644C5E0C9A3DBB336F68D178417FA2DFE557CB963ACB4847E87008D82B794D6BBD4B3D52390A60D89C96A9FF15AA5DB342488578F17645D35DDC933C784B3DD5FA526865B6C9D38470633E375D2E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=E6A891D2134F30C0&aid=7BF286E46F6BB7E72389051ED0EA34D1&vid=&iid=F3090AE9B60B7ED1&sid=CA0B5EEC0BAD621A&eid=80B081C203919926&fileno=20251006&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="E6A891D2134F30C0"; var my_aid="7BF286E46F6BB7E72389051ED0EA34D1";