Ding Wei,Liu Ziyan,Ma Zepeng,et al.Comparison of automatic tube voltage modulation combined with an artificial intelligence iterative reconstruction algorithm versus conventional scanning protocol in contrast-enhanced thoracic-abdominal-pelvic CT[J].Chinese Journal of Radiological Medicine and Protection,2025,45(7):692-698
Comparison of automatic tube voltage modulation combined with an artificial intelligence iterative reconstruction algorithm versus conventional scanning protocol in contrast-enhanced thoracic-abdominal-pelvic CT
Received:June 12, 2024  
DOI:10.3760/cma.j.cn112271-20240612-00222
KeyWords:Artificial intelligence iterative reconstruction  Contrast-enhanced thoracic-abdominal-pelvic CT  Optimal noise level  Image quality  Radiation dose
FundProject:
Author NameAffiliationE-mail
Ding Wei Department of Radiology, Affiliated Hospital of Hebei University, Baoding 071000, China  
Liu Ziyan Department of Radiology, Affiliated Hospital of Hebei University, Baoding 071000, China  
Ma Zepeng Department of Radiology, Affiliated Hospital of Hebei University, Baoding 071000, China  
Zhang Tianle Department of Radiology, Affiliated Hospital of Hebei University, Baoding 071000, China  
Zhao Yongxia Department of Radiology, Affiliated Hospital of Hebei University, Baoding 071000, China zyx_zyx999@163.com 
Hits: 4108
Download times: 1027
Abstract::
      Objective To evaluate the image quality and radiation dose in contrast-enhanced thoracic-abdominal-pelvic CT using automatic tube voltage modulation (ATVM) coupled with artificial intelligence iterative reconstruction (AIIR) versus routine tube voltage combined with Karl-3D iterative reconstruction (Karl-3D IR), and to determine the optimal noise level for AIIR in contrast-enhanced thoracic-abdominal-pelvic CT. Methods A total of 100 patients who underwent contrast-enhanced thoracic-abdominal-pelvic CT examination in the Affiliated Hospital of Hebei University from April to October, 2023 were randomly divided into group A and group B using a random number table, with 50 patients in each group. Group A was scanned using ATVM, and images were reconstructed using AIIR with 1-5 noise levels. Group B was scanned using tube voltage 120 kVp and images were reconstructed with Karl-3D IR and noise level 5. The single-to-noise ratio (SNR), contrast-to-noise ratio (CNR), effective dose (E), and size-specific dose estimate (SSDE) were recorded or calculated for all patients or images. Subjective evaluations of all images were performed. The quality of the reconstructed images using AIIR with 1-5 noise levels were compared and the optimal noise level of AIIR for image reconstruction was determined. Image quality and radiation dose were statistically analyzed for Group A (image reconstruction with optimal AIIR noise level) and Group B. Results The mean SNR and mean CNR of the reconstructed images using AIIR with noise levels 1, 2, and 3 in group A were higher than those using AIIR with noise levels 4 and 5. The images reconstructed using AIIR with noise levels 3 and 4 scored higher in subjective assessment than those reconstructed using AIIR with noise levels 1, 2, and 5. Therefore, noise level 3 was optimal for AIIR in reconstruction of contrast-enhanced thoracic-abdominal-pelvic CT images. The mean SNR, mean CNR, and subjective evaluation score of group A using AIIR with noise level 3 were higher than those of group B using Karl-3D IR with noise level 5 (P<0.001). The mean SSDE and the mean E of group A were reduced by 46% and 41%, respectively, compared with those of group B. Conclusions ATVM technology combined with the AIIR algorithm can improve image quality and reduced patient radiation dose in contrast-enhanced thoracic-abdominal-pelvic CT. Noise level 3 is optimal for AIIR in the reconstruction of arterial-phase and venous-phase contrast-enhanced thoracic-abdominal-pelvic CT images.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:17875073  On-line:0

v
Scan QR Code
&et=8C10CEA789A144B8200CF6B32FC36480C34EA2700DEDB2F2B74E408753DFBF84890436F06C752474A9D1B69C3579C77182B9608B24773FBE149238AB9F99915E33021779DBA067BFB772889907500871A344CA0C2CCC05599F5569CFA5FD76EAA9E8894CBA94F7E80D85DEDD12C29A9DA8FE603FFB0E09592C509B9DFE5C2BB335943B0A048893FB4657B5FF10B781CE8516535DC8533F3CFBC0D6A9546A79BB31F101B104DE0C69342E760061F8684039BD6D5F4CCF80DE338EAEF4C5B15F4D10B8FDDA1184FF641BD38248B158557E9F46886D2F939540&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=E6A891D2134F30C0&aid=6F877BFB6D17052EC58A4CD12398A59A&vid=&iid=DF92D298D3FF1E6E&sid=15F713CDE16A589C&eid=6CDD207A90CE1EEC&fileno=20250711&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="E6A891D2134F30C0"; var my_aid="6F877BFB6D17052EC58A4CD12398A59A";