Wang Yiling,Zhao Yue,Liu Qiuhan,et al.Automatic target volume tracking in magnetic resonance imaging-guided radiotherapy based on artificial intelligence[J].Chinese Journal of Radiological Medicine and Protection,2025,45(6):558-565
Automatic target volume tracking in magnetic resonance imaging-guided radiotherapy based on artificial intelligence
Received:July 11, 2024  
DOI:10.3760/cma.j.cn112271-20240711-00257
KeyWords:Magnetic resonance image-guided radiotherapy  Deep learning  Cine magnetic resonance image  Target volume tracing
FundProject:四川省科技计划资助项目(2023YFH0079,2023NSFSC0720);国家自然科学基金(61901087)
Author NameAffiliationE-mail
Wang Yiling Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, University of Electronic Science and Technology of China, Chengdu 610041, China  
Zhao Yue Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, University of Electronic Science and Technology of China, Chengdu 610041, China  
Liu Qiuhan Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, University of Electronic Science and Technology of China, Chengdu 610041, China  
Wang Jie Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, University of Electronic Science and Technology of China, Chengdu 610041, China  
Fan Yu Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, University of Electronic Science and Technology of China, Chengdu 610041, China fanyu@scszlyy.org.cn 
Hits: 139
Download times: 49
Abstract::
      Objective To explore the feasibility of automatic target volume tracing in the Elekta Unity magnetic resonance imaging (MRI)-guided radiotherapy system and to further enhance the real-time target volume tracing performance of MRI-guided radiotherapy by introducing the deep learning technology based on a large Transformer model. Methods A total of 4 661 frames of cine MRI binary images from 75 patients with malignant tumors in the chest/abdomen who were treated with MRI-guided radiotherapy were retrospectively collected as a training set. Another 500 frames of cine MRI binary images from 10 patients were collected as an independent test set. A module for medical image format conversion was developed to convert binary images into medical meta-images. The outer contours of tumor target volumes in the cine MRI images of the test set were manually delineated as actual control labels. With the first frame of the cine MRI images of each patient as the reference image and the other frames as motion images, a Transformer-based deep learning model was constructed to describe the deformable vector field (DVF) of motion images relative to the reference image. The Dice similarity coefficient (DSC), the 95% Hausdorff distance (HD95), the negative Jacobian determinant (NegJ), and the average processing time per frame of cine MRI images were calculated. These values were compared to those of the conventional B-Spline scheme to quantitatively assess the target volume tracing accuracy, DVF physical plausibility, and execution efficiency of the Transformer-based deep learning model. Results The Transformer-based deep learning model constructed in this study delivered superior target volume tracing performance, with improved DSC [(0.84 ± 0.05) vs.(0.74 ± 0.16), t = 11.44, P < 0.05] and HD95 [(9.25 ± 2.98) vs.(14.70 ± 8.55) mm, t= -11.83, P < 0.05]. Furthermore, this model reduced the average image processing time from 1.95 s to 30.99 ms, enhancing the efficiency by two orders of magnitude. Besides, this model yielded NegJ similar to that of the B-Spline scheme. This suggests that the DVF extracted using this model had comparable physical plausibility with that obtained using the B-Spline scheme. Conclusions The Transformer-based deep learning model for automatic target volume tracing fills the functional gap of the Elekta Unity MRI-guided radiotherapy system, facilitating relatively accurate, efficient automatic tracing of moving tumor targets in the chest and abdomen.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12036136  On-line:0

v
Scan QR Code
&et=E6FEEF1BF808351777B64CA450D270D646AB57813B92E0E17CE275C3498FA8173229472FB04D90EB163E762E9236AFFF979A828CA043ACECF12D8EEBD6DDA5C7BD7DD9B018CFB0D079FF3434984F16DB664C6AD5544FED6117B163CBB52CD3A373A9E719254226E5701E9B8BFC53B12BF5374F11A6A50A5E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=E6A891D2134F30C0&aid=&vid=&iid=B31275AF3241DB2D&sid=C7A2B92569DF5458&eid=90075EB19043D533&fileno=20250610&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="E6A891D2134F30C0"; var my_aid="";