Zhou Wanyi,Hu Ankang,Li Junli,et al.Features and challenges of radiation shielding design of FLASH radiotherapy rooms[J].Chinese Journal of Radiological Medicine and Protection,2025,45(4):374-379 |
Features and challenges of radiation shielding design of FLASH radiotherapy rooms |
Received:July 11, 2024 |
DOI:10.3760/cma.j.cn112271-20240711-00259 |
KeyWords:FLASH radiotherapy Radiation protection standards Dose control limits |
FundProject:国家自然科学基金(12405359, 12175114, U2167209, 12375312) |
Author Name | Affiliation | E-mail | Zhou Wanyi | Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China | | Hu Ankang | Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China | | Li Junli | Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China | | Qiu Rui | Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China | qiurui@tsinghua.edu.cn |
|
Hits: 258 |
Download times: 97 |
Abstract:: |
FLASH radiotherapy is moving from animal experiments to clinical trials. However, the research on radiation shielding of FLASH radiotherapy rooms has been still in the initial stage. This paper analyses the structural characteristics of the beam pulse of FLASH radiotherapy devices of different technical routes, and discusses the radiation shielding challenges facing the radiotherapy room from FLASH radiotherapy technology based on the current protection standards for the radiotherapy room at home and abroad. The purpose is to provide input to the research on radiation protection of FLASH radiotherapy and to promote the clinical development of FLASH radiotherapy. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|