Wang Jinghang,Chen Bo,Zhuo Weihai.A new software for rapid estimation of external dose to the public due to environmental radioactive contamination[J].Chinese Journal of Radiological Medicine and Protection,2023,43(10):805-811
A new software for rapid estimation of external dose to the public due to environmental radioactive contamination
Received:April 18, 2023  
DOI:10.3760/cma.j.cn112271-20230418-00125
KeyWords:Radioactive contamination  External exposure  Equivalent dose  Effective dose  Software tool
FundProject:国家自然科学基金(12175043)
Author NameAffiliationE-mail
Wang Jinghang Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Chen Bo Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Zhuo Weihai Institute of Radiation Medicine, Fudan University, Shanghai 200032, China whzhuo@fudan.edu.cn 
Hits: 811
Download times: 298
Abstract::
      Objective To develop a software for rapid estimation of external dose to the public due to environmental radioactive contamination. Methods Based on the data provided by the International Commission on Radiological Protection (ICRP), a database of the conversion coefficients of external dose rates for the public (adult and children of different age groups) under different environmental exposure scenarios was created. The programs of data search and calculation were written using Python language, and the software interface was designed using PyQt toolkit. To test the calculation results, the differences in external doses to different age groups of the public caused by most likely produced radionuclides under three environmental exposure scenarios were calculated, and their rationalities were analyzed. Results The software can immediately complete the estimation of the organ equivalent doses and the effective dose due to the external exposure form environmental contamination by using a personal computer with a Windows system, and its results are reasonable. The test results showed that the younger the public members, the larger the organ dose and effective dose. For soil surface and water contaminated with 90Sr with the same activity concentration reaching radioactive equilibrium, the effective dose to infants was about 6.08 times and 2.51 times those to adults, respectively. Conclusions The software developed in this study has the advantages of simple operation and fast calculation, and is suitable for rapid estimation of external dose to the public members of different age groups in emergency situations such as nuclear accidents.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9079106  On-line:0

v
Scan QR Code
&et=9DC69FA66ACBAFBA16594EA649CD16B7E335948031AA8DB18559C857A6411E26C212F7A64FD9A7B59FB7597D13332D7D3F758CACC80B72B3AE72651C6359CB3C04840E435165E4259C84989B97FB4BD9B0A47F478CF63307763B9A433B75E3E4143B1F793314663F08209628AF17399146F442559A8054D1&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BA1E75DF0B7E0EB2&aid=4B4F1E23B8EE25F072FA0AEAD0E91354&vid=&iid=F3090AE9B60B7ED1&sid=8C8D39B86A1EED4F&eid=A9C78B2A6AAEEAAD&fileno=20231008&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BA1E75DF0B7E0EB2"; var my_aid="4B4F1E23B8EE25F072FA0AEAD0E91354";