Li Tiantian,Li Peng,Sun Weihang,Min Nan,Liu Fang,Li Zhen,Zhu Jianguo,Niu Fei.Measurement and evaluation of thyroid 131I activity in iodine treatment workers[J].Chinese Journal of Radiological Medicine and Protection,2022,42(11):888-891
Measurement and evaluation of thyroid 131I activity in iodine treatment workers
Received:July 15, 2022  
DOI:10.3760/cma.j.cn112271-20220715-00291
KeyWords:Internal exposure  131I  Thyroid  Radiation dose
FundProject:山东省医药卫生科技发展计划项目(2017WS272)
Author NameAffiliationE-mail
Li Tiantian Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China  
Li Peng Jining Center for Disease Control and Prevention, Jining 272000, China  
Sun Weihang Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China  
Min Nan Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China  
Liu Fang Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China  
Li Zhen Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China  
Zhu Jianguo Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China  
Niu Fei Shandong First Medical University (Shandong Academy of Medical Sciences), College of Preventive Medicine (Institute of Radiation Medicine), Jinan 250117, China niufei@sdfmu.edu.cn 
Hits: 1255
Download times: 411
Abstract::
      Objective To understand the 131I activity in thyroid of therapy workers in nuclear medicine department, and estimate the annual committed effective dose, in order to analyze the internal exposure of them.Methods Six hospitals were investigated and 131I activity of thyroid was measured. The detection rate and activity value of thyroid 131I activity of therapy workers in nuclear medicine department were obtained from the six hospitals, and then the intake and annual committed effective dose were calculated.Results A total of 63 iodine therapy workers from six hospitals were measured and 131I was detected for 52 workers among them, with the detection rate of 83% and 131I activities mostly lower than 200 Bq. The estimated annual committed effective dose ranged from 0.23 to 7.78 mSv. The annual committed effective dose to 84.6% of the workers was less than 2 mSv.Conclusions Iodine therapy workers in nuclear medicine department should receive routine internal exposure personal monitoring, and the radiation protection system in all hospitals needs to be further improved.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9061848  On-line:0

v
Scan QR Code
&et=DC44477595533BA79D4991F2B6CA64D00573A70EE3703F4FE1EB1876B85DC809AA1B36145FC974962698EB1A23E687C292C9811B10D511FCCCFB87A71D7E43669D7EAEAD0368B31F6B4D159165AB3FDD55FF679FBFBA7F518EE345C62B485467&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=A774FB5325A1D53F2FE987F95A5733DD&vid=&iid=708DD6B15D2464E8&sid=68BCD01D0D745EB3&eid=412FA1328E0CB9E9&fileno=20221115&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="A774FB5325A1D53F2FE987F95A5733DD";