Yuan Han,Gong Wenjing,Han Xuelei,Cao Shaofei,Li Jianguo.Establishment and Application of dose evaluation model for typical mammal in dry region in China[J].Chinese Journal of Radiological Medicine and Protection,2022,42(10):793-798
Establishment and Application of dose evaluation model for typical mammal in dry region in China
Received:May 24, 2022  
DOI:10.3760/cma.j.cn112271-20220524-00219
KeyWords:Rabbit  Simplified anatomical model  Dose coefficients  ERICA tool
FundProject:中国辐射防护研究院纵向项目
Author NameAffiliation
Yuan Han China Institute for Radiation Protection, Taiyuan 030006, China 
Gong Wenjing China Institute for Radiation Protection, Taiyuan 030006, China 
Han Xuelei China Institute for Radiation Protection, Taiyuan 030006, China 
Cao Shaofei China Institute for Radiation Protection, Taiyuan 030006, China 
Li Jianguo China Institute for Radiation Protection, Taiyuan 030006, China 
Hits: 1263
Download times: 409
Abstract::
      Objective To establish a simplified anatomical model with the selected rabbits widely distributed in China's dry region as the reference species and compare the result of internal exposure dose coefficients based on the present mode and ERICA.Methods A simplified anatomical model based on anatomy and geometry was established for rabbits. Combined with Monte Carlo program, the deposited energy of radionuclide particles in rabbit tissues/organs was obtained, and the internal and external exposure dose coefficient for rabbits was calculated following the empirical formula.Results Simplified anatomy model-based dose coefficients were 129I 4.81 × 10-6, 137Cs 4.34 × 10-5, and 134Cs 3.81 × 10-5(μGy·h-1)/(Bq·kg-1) for internal exposure and 129I 3.16 × 10-7,137Cs 2.39 × 10-4 and 134Cs 6.22 × 10-4(μGy·h-1)/(Bq· kg-1) for external exposure. respectively. ERICA-based dose coefficients were 129I 4.44 × 10-5, 137Cs 1.94 × 10-4 and 134Cs 2.34 × 10-4(μGy·h-1)/(Bq·kg-1) for internal exposure and 129I 2.19 × 10-6, 137Cs 2.52 × 10-4 and 134Cs 6.95 × 10-4(μGy·h-1)/(Bq·kg-1) for external exposure, respectively.Conclusions The simplified anatomical model established is based on the measured data and focuses on the radiation doses to biological tissues/organs, and the calculated result based on the present model are closer to the actual situation, and can provide reference values for the reference biological evaluation of non-human species.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9071258  On-line:0

v
Scan QR Code
&et=909BCF45EAE28FE8CF015A77D8612E02301C43F270B556451F0684157E883F688C12A3F46C70E7DBEAB453B62B77BA47208DA34BFC36055E9B9C99BBC180B882FE79DF5836664760522D4EDD35EFAB28C4D4245D060959F024B28E18CDB87EA7C7C5D81C226F9161&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=D3D649D0ACA5A49339FD0F728557706E&vid=&iid=F3090AE9B60B7ED1&sid=8225A9F184D4F1CA&eid=B3645A659773B73C&fileno=20221012&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="D3D649D0ACA5A49339FD0F728557706E";