Lu Liyan,Wang Kongzhao,Xiong Kouhong,et al.Direct measurement of urine tritium and estimation of internal doses to personnel at pressurized heavy water reactor nuclear power plants[J].Chinese Journal of Radiological Medicine and Protection,2022,42(7):544-548
Direct measurement of urine tritium and estimation of internal doses to personnel at pressurized heavy water reactor nuclear power plants
Received:January 05, 2022  
DOI:10.3760/cma.j.cn112271-20220105-00004
KeyWords:Tritium  Internal exposure  Monitoring  Dose estimate  Dead time
FundProject:苏州大学附属第二医院学科建设托举工程核技术医学应用创新团队项目(XKTJ-HTD2021001)
Author NameAffiliationE-mail
Lu Liyan Department Three of Health Physics, CNNC Nuclear Power Operations Management Co., Ltd., Haiyan 314300, China  
Wang Kongzhao Department Three of Health Physics, CNNC Nuclear Power Operations Management Co., Ltd., Haiyan 314300, China  
Xiong Kouhong Radiation Safety Institute, Nuclear Power Operations Research Institute, Shanghai 200216, China  
Liu Yulong Department of Oncology, Second Affiliated Hospital of Soochow University, Suzhou 215004, China yulongliu2002@126.com 
Hits: 3638
Download times: 1163
Abstract::
      Objective To explore the optimization of tritium internal exposure monitoring and dose estimation for radiation workers at pressurized heavy water reactor nuclear power plants (PHWR NPPs). Methods A total of 92 radiation workers at Candu-6 PHWR NPPs were observed to calculate the distribution of quenching index (tSIE). Ten samples with tSIE values ranging from 160 to 460 were selected to make the blank urine quenching curve. By comparing with the quenching curve accompined with the equipment, the optimization of correlationship of urine tritium measurement system was carried out. In estimating tritium internal radiation dose, the dose coefficient was optimized and adjusted by comparing the Canadian algorithm with the national standard algorithm. Dead time correction curve was drawn by means of heavy water simulation experiment diluting main heat transfer system. Results Through the analysis and optimization of tritium internal dose estimation, the optimal dose coefficient was determined to be 4.8 and the quenching curve of blank urine sample was made. By comparison, it was found that the deviation was larger when tSIE<200, which confirmed the necessity of blank curve. When the tritium concentration in urine was higher than 2.4×104 Bq/ml, the urine sample needed to be diluted and then measured to correct the effect of death time. Conclusions By optimizing both tritium internal exposure monitoring and dose estimation, not only the collective dose management can be improved, but also the unplanned tritium intake can be detected and treated in time, which plays an important role in ensuring the protection and safety of the radiation workers at PHWR NPPs.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029530  On-line:0

v
Scan QR Code
&et=8C721905AC0458B654C600CBD0925C725E6811D8ED0C63BBC1558764D38CA3C221EC790A825EB325928A4537DD160DA6BE94667E7BCF0DC21B5BCD8F47C46A971EE80B77DB18A0E9D881CB308763708360E767E821DCA8B19110229FFC82B32703CF89C8FC1A638E46C69C06F3A20AC91B6F84F095AFA2AC3ADD02548FA250592059D26C3E34063063CB5D689A9339E2&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=CB8076C253AD48E63D9DE89FE1356C13&vid=&iid=DF92D298D3FF1E6E&sid=B34BDD6A690A04C0&eid=E5D85F291CED2DA6&fileno=20220712&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="CB8076C253AD48E63D9DE89FE1356C13";