Wang Xun,Shi Qiang,Wang Xiaofeng,Xiao Pengjun,Cheng Tianheng.Analysis of causes and countermeasures against marine organisms blocking event at cold source intake of coastal nuclear power plant[J].Chinese Journal of Radiological Medicine and Protection,2022,42(4):309-314
Analysis of causes and countermeasures against marine organisms blocking event at cold source intake of coastal nuclear power plant
Received:January 06, 2022  
DOI:10.3760/cma.j.cn112271-20220106-00006
KeyWords:Nuclear power plants|Cooling water system|Nuclear safety|Blockage
FundProject:国家自然科学基金(11775145);上海市公共卫生重点学科建设计划项目(GWV-10.1-XK10);上海市公共卫生优秀学科带头人计划项目(GWV-10.2-XD16)
Author NameAffiliationE-mail
Wang Xun Chief Engineer's Office, Nuclear and Radiation Safety Center of Ministry of Ecology and Environment, Beijing 100082, China  
Shi Qiang Chief Engineer's Office, Nuclear and Radiation Safety Center of Ministry of Ecology and Environment, Beijing 100082, China s_qiang1987@163.com 
Wang Xiaofeng Chief Engineer's Office, Nuclear and Radiation Safety Center of Ministry of Ecology and Environment, Beijing 100082, China  
Xiao Pengjun Division Ⅲ of Nuclear Facilities Supervision, South China Nuclear and Radiation Safety Supervision Station of Ministry of Ecology and Environment, Shenzhen 518034, China  
Cheng Tianheng Chief Engineer's Office, Nuclear and Radiation Safety Center of Ministry of Ecology and Environment, Beijing 100082, China  
Hits: 1811
Download times: 726
Abstract::
      The cold source system of a nuclear power plant, as important part of a nuclear power project, is of great significance to guarantee the safe operation of a nuclear power plant. In recent years, there have been some cases of marine organism blockage at cold source intake at coastal nuclear power plants in China, which has adversely affected the safety and economy of nuclear power plants. According to the research result of cold source safety in coastal nuclear power plants in China and in compliance with the requirements of nuclear safety regulatory control and the engineering practice experience, the causes of, and countermeasures against, marine organism blockage at cold source intake are analyzed to further improve the safety and economy of nuclear power plants.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9067654  On-line:0

v
Scan QR Code
&et=6FD48CA0A0DD4759C1ACF8ED304297BC414A35C7374FB6F1D29C5F5BA1B1A278A49464E01AC6602C17AA3DAD095BB21C253FC3F82F3E6B2419BA58822222006F1AF8FA88D0167953CAEE10B087316BA8A5DF9ADBD33F9665AFE8B9FE22B716AFF4E6D0262EA80A04B2F44E5ADC34DC8F04B68DF722052D20C2EEF2688AD32B12DAD0B4A5F003B707&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=2D57B55F09E69D01C149118C0A486682&vid=&iid=E158A972A605785F&sid=F637763636425CAF&eid=AA5FB09E1F81059E&fileno=20220411&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="2D57B55F09E69D01C149118C0A486682";