Ji Zhigang,Li Tianlai,Xu Yi,Zhao Xianfeng,Wang Yao,Wang Wubin,Tian Yanpeng.Monitoring and analysis of lens dose to interventional radiology workers at some hospitals in Shaanxi province from 2018 to 2020[J].Chinese Journal of Radiological Medicine and Protection,2022,42(1):55-60
Monitoring and analysis of lens dose to interventional radiology workers at some hospitals in Shaanxi province from 2018 to 2020
Received:June 07, 2021  
DOI:10.3760/cma.j.cn112271-20210607-00236
KeyWords:Interventional radiology  Lens of the eye  Annual equivalent dose
FundProject:
Author NameAffiliationE-mail
Ji Zhigang Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China  
Li Tianlai Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China 124933647@qq.com 
Xu Yi Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China  
Zhao Xianfeng Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China  
Wang Yao Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China  
Wang Wubin Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China  
Tian Yanpeng Radiation and Occupational Health Institute, Shaanxi Provincial Center for Disease Control and Prevention, Xi'an 710054, China  
Hits: 2218
Download times: 854
Abstract::
      Objective To analyze and learn about the dose to the lens of the eye of interventional radiology workers in some hospitals in shaanxi province from 2018 to 2020.Methods From 2018 to 2020, three tertiary hospitals in shaanxi province were selected to monitor the dose to the lens of the eye of interventional radiology workers for three consecutive years. Monitoring was made for 152 person times, lasting for a monitoring period of 3 months. Analysis and comparison were carried out of dose equivalents to the interventional radiology workers in terms of different sexes, positions and departments, together with associated influencing factors during the three years.Results The difference in equivalent dose between the three years is statistically significant (χ2=29.15, P < 0.05), and a downward trend in the average annual equivalent dose was found from 2018 to 2020. The number of interventional radiology workers who received doses to the lens of the eye mainly between MDL and 5.0 mSv accounted for 69.08%. The difference in the average annual equivalent dose in different positions and departments was statistically significant (H=18.44, 22.55, P < 0.05). The average annual equivalent dose to doctor was higher than for nurses and technicians (Z=-3.36, -3.02, P < 0.05). The average annual equivalent dose in cardiovascular medicine department was higher than in other departments, with statistically significant difference (Z=-2.58, -3.76, -3.40, P < 0.05). Logistics regression analysis showed that radiation working hours, positions, routine personal doses, workload and exposure time are the factors that affect the average annual equivalent dose.Conclusions The annual equivalent dose to the lens of the eye of interventional radiology workers in shaanxi province meets the relevant national standards. However, the annual dose to some radiological workers has a normal high value. Therefore, it is necessary to strengthen the continued monitoring of the dose to the lens of the eye of the interventional radiology workers, and adjust the types of work for the workers based on radiation work hours, position, routine personal dose, workload and exposure time, so as to effectively reduce the dose level of the eye lens.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9073944  On-line:0

v
Scan QR Code
&et=3CBA26923B150914F81C81130989E12E1A1135431530C0AF580593CB2388D24EA8B86CA4A51BBEDA3E7E559F26AE3F69E84F11E4982CCA173A9DD19EBFF50028651A63561D053837CD80B5F976EDF52DBC46E29CDFC6EFD6EA96871BC7ADD8572FD2863685EFF30F84A750E401713732DB3ECDE2630CA885A75F0EFFF764A22164F1D20F3785A5BC&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=885CEFEC57DA488F&aid=BAE5A74472E7046FF6A0A2D6C3285877&vid=&iid=CA4FD0336C81A37A&sid=E514EE58E0E50ECF&eid=BFE7933E5EEA150D&fileno=20220110&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="885CEFEC57DA488F"; var my_aid="BAE5A74472E7046FF6A0A2D6C3285877";