Gong Wenjing,Zhang Sheng,Zhang Chao,et al.Establishment and application of typical insect dose model in northwestern China[J].Chinese Journal of Radiological Medicine and Protection,2021,41(11):856-861
Establishment and application of typical insect dose model in northwestern China
Received:March 06, 2021  
DOI:10.3760/cma.j.issn.0254-5098.2021.11.011
KeyWords:Damalacore  Simplified anatomical model  Voxel model  Dose coefficients  Dose rate
FundProject:
Author NameAffiliation
Gong Wenjing China Institute for Radiation Protection, Taiyuan 030006, China 
Zhang Sheng China Institute for Radiation Protection, Taiyuan 030006, China 
Zhang Chao China Institute for Radiation Protection, Taiyuan 030006, China 
Li Jianguo China Institute for Radiation Protection, Taiyuan 030006, China 
Hits: 3224
Download times: 1336
Abstract::
      Objective To validate the feasibility of establishing a dosimetric model for insect species by investigating the ecological environment of an inland site in the northwestern China. Methods For Damalacore, a simplified anatomical model based on anatomy and geometry and a model based on CT scan sequence image were established to produce a voxel model. In combination with the Monte Carlo particle transport process, the deposited energy of the radionuclides in the insect tissues/organs was obtained. The dose rate from 90Sr and 137Cs to Damalacore was calculated on the basis of empirical formula. Results The dose rate from internal exposure to the simplified anatomical model was 8.58×10-2 for 90Sr and 4.25×10-3μGy/h for 137Cs, whereas the dose rate from external exposure to the simplified anatomy model was 2.81×10-2for 90Sr and 2.56×10-1μGy/h for 137Cs, respectively. The internal exposure to the voxel model from 90Sr and 137Cs was 3.91×10-2and 2.91×10-3μGy/h, whereas the external exposure to the voxel model from 90Sr and 137Cs was 2.81×10-2 and 2.56×10-1μGy/h, respectively. The internal exposure from 90Sr and 137Cs to ERICA model was 1.46×10-1 and 1.46×10-2μGy/h, whereas the external exposure to the ERICA model from 90Sr and 137Cs was 5.79×10-2 and 2.58×10-1μGy/h, respectively. Conclusions The calculated results based on the two models are similar to those based on ERICA model and therefore are proved reliable. With improved model accuracy, the calculated result are more close to the practical situation and feasible.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12029912  On-line:0

v
Scan QR Code
&et=909BCF45EAE28FE8CF015A77D8612E025F35541E53DAC320D72035760669801719F38F1B56DBE992A261A963B67315FBCA3FDE225D01B41CA552A37205CD5BB6B623FA40BC1F8AABEA426960E4CC95B739199A9A9C608380&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=8356581D7B9EC80D49CB454DDB0463F1&vid=&iid=708DD6B15D2464E8&sid=353B961D86F026C0&eid=0B757E9DCA0EC579&fileno=20211111&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="8356581D7B9EC80D49CB454DDB0463F1";