Chen Xin,Zhang Weiyuan,Zhuo Weihai.Estimation of patient doses in paediatric cardiovascular interventional radiology under specific exposure conditions[J].Chinese Journal of Radiological Medicine and Protection,2021,41(3):199-204
Estimation of patient doses in paediatric cardiovascular interventional radiology under specific exposure conditions
Received:December 31, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2021.03.008
KeyWords:Cardiovascular intervention  Organ dose  Monte Carlo method  Dose area product  Field of view
FundProject:Shanghai Municipal Commission of Health and Family Planning (20174Y0140)
Author NameAffiliationE-mail
Chen Xin Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Zhang Weiyuan Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Zhuo Weihai Institute of Radiation Medicine, Fudan University, Shanghai 200032, China whzhuo@fudan.edu.cn 
Hits: 2034
Download times: 1108
Abstract::
      Objective To estimate the organ doses and effective doses to different-age children during cardiovascular interventional radiological procedures under some specific exposure conditions, and explore the main influencing factors on the doses. Methods Based on the paediatric reference computational phantoms recommended in the ICRP Publication 143, several specific exposure models of cardiovascular intervention were built, and the Monte Carlocook MCNPX 2.7.0, was used to calculate the organ doses and effective doses for 1-, 5-, 10- and 15-year-old children. To validate the simulation result, an experiment was implemented by putting the thermoluminescent dosimeters in a 5-y old phantom (ATOM 705-D) manufactured by the CIRS Inc. in the USA. Results Both the height and weight of the reference children for 1-, 5- and 10-year-old provided for by Chinese national standards are nearly in consistency with those recommended by ICRP, and even for the 15-year-old, the maximum relative deviations of the height and weight are only -1.9% and -5.7%, respectively. Under the exposure condition where the focal spot to image receptor distance (SID) was 90 cm, the length of square field of view (FOV) was 30 cm with a dose area product (DAP) of 45 Gy·cm2, the relative deviations between simulated and measured doses to main organs/tissues within the irradiation filed were within ±6.7%. Under the same exposure conditions, the younger the children, the larger the organ doses and effective doses, and the effective doses could vary by a factor of about 5 among the 4 age groups. The conversion coefficient between the organ dose and the value of DAP was not only closely related to the age of children, but also affected by the FOV. Conclusions In combination with the paediatric reference computational phantoms and the exposure models of cardiovascular intervention, the Monte Carlo method can be used to calculate the doses to children undergoing cardiovascular interventional radiological procedures. The information on the values of DAP and FOV as well as the directions of projection are needed for more accurate estimation of the exposure doses.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9064051  On-line:0

v
Scan QR Code
&et=EC9A7F1C2771EE50E9DCB2BBDB8967429764EE7D4845EEA4A6807E50FFACDFF1AA48789ED4831AA6FF81492917AD82EB17531FF9B9A457D5D48FAFDB6D1A6966D80AB642CBBC0B8F7AF52222E27E0F5DA5B9821A60C1BB8E2BF49C17B05E07F6C396DCE6B411C9D4D8C846F2F456739D8498648E236D583A&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9475FABC7A03F4AB&aid=D82BB2A69777A4C9E29B7F40E29E91D1&vid=&iid=38B194292C032A66&sid=FCD27DC5E1F2EEE7&eid=02DC3A182A5530DF&fileno=20210308&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9475FABC7A03F4AB"; var my_aid="D82BB2A69777A4C9E29B7F40E29E91D1";